Your browser doesn't support javascript.
loading
Iliac Branch Devices in the Repair of Ruptured Aorto-iliac Aneurysms: A Multicenter Study.
Karelis, Angelos; Sonesson, Björn; Gallitto, Enrico; Tsilimparis, Nikolaos; Forsell, Claes; Leone, Nicola; Silingardi, Roberto; Mesnard, Thomas; Sobocinski, Jonathan; Isernia, Giacomo; Resch, Timothy; Gargiulo, Mauro; Dias, Nuno V.
Afiliação
  • Karelis A; Vascular Center, Department of Thoracic Surgery and Vascular Diseases, Skåne University Hospital, Malmö, Sweden.
  • Sonesson B; Vascular Center, Department of Thoracic Surgery and Vascular Diseases, Skåne University Hospital, Malmö, Sweden.
  • Gallitto E; Division of Vascular Surgery, IRCCS Azienda Ospedaliero-Universitaria di Bologna, University of Bologna, Bologna, Italy.
  • Tsilimparis N; German Aortic Center Hamburg, Department of Vascular Medicine, University Heart & Vascular Center Hamburg, Hamburg, Germany.
  • Forsell C; Department of Cardiothoracic Surgery and Cardiothoracic Anesthesia, Linköping University Hospital, Linköping, Sweden.
  • Leone N; Department of Vascular Surgery, University of Modena and Reggio Emilia, Modena, Italy.
  • Silingardi R; Department of Vascular Surgery, University of Modena and Reggio Emilia, Modena, Italy.
  • Mesnard T; Department of Vascular Surgery, Aortic Centre, CHU Lille, Lille, France.
  • Sobocinski J; Inserm, CHU Lille, Université de Lille, Lille, France.
  • Isernia G; Department of Vascular Surgery, Aortic Centre, CHU Lille, Lille, France.
  • Resch T; Unit of Vascular and Endovascular Surgery, Santa Maria della Misericordia Hospital, Perugia, Italy.
  • Gargiulo M; Department of Vascular Surgery, Faculty of Health and Medical Sciences, Copenhagen University Hospital, University of Copenhagen, Copenhagen, Denmark.
  • Dias NV; Division of Vascular Surgery, IRCCS Azienda Ospedaliero-Universitaria di Bologna, University of Bologna, Bologna, Italy.
J Endovasc Ther ; : 15266028221149922, 2023 Jan 22.
Article em En | MEDLINE | ID: mdl-36683380
PURPOSE: To evaluate the outcomes of preserving the internal iliac artery (IIA) with iliac branched devices (IBDs) during acute endovascular repair of ruptured aortoiliac aneurysms. MATERIAL AND METHODS: This is a multicenter retrospective review of all consecutive patients undergoing acute endovascular repair of ruptured aortoiliac aneurysm with an IBD at 8 aortic centers between December 2012 and June 2020. A control group was used where the IIA was intentionally occluded from the same study period. The main outcome measures were 30-day mortality, major adverse events, technical success, and clinical success. Secondary outcomes were buttock claudication, primary patency, primary-assisted and secondary patency of the IBD, occurrence of endoleak types I/III, and reintervention. Values are presented as numbers and percentages or interquartile range in parenthesis. RESULTS: Forty-eight patients were included in the study: 24 with IBD and 24 with IIA occlusion. There was no difference in demographics, cardiovascular risk factors, and aneurysm extent. Twenty (83%) of them were hemodynamically stable during the procedure as opposed to 14 (58%, p=.23) with the IIA occlusion. Technical success was achieved in all cases with a procedure time of 180 (133-254) minutes, 45 (23-65) of which were from IBD. There were 2 (8%) deaths during the first 30 days and 2 (8%) major complications unrelated to the IBD, whereas in the IIA occlusion, the figures were 10 (42%) and 7 (29%), respectively. No patient in the IBD group developed buttock claudication compared to 8 (57%, p<.0001) in the IIA occlusion group; 1 (4%) patient developed bowel ischemia on both groups, with 1 in the IIA occlusion group needing resection. The median follow-up duration was 17 months (interquartile range 2-39) for the IBD group, with a primary patency of 60±14% at 3 years that went up to 92±8% with reinterventions (8 reinterventions in 6 patients). When the first 90 days were disregarded, there were no differences in survival between the groups. CONCLUSION: IBD is a valid alternative for maintaining the pelvic circulation for endovascular aortic aneurysm repair of ruptured aortoiliac aneurysms. The technical success and midterm outcomes are very satisfactory but require patient selection particularly regarding hemodynamic stability. The reintervention rate is considerable, mandating continuous follow-up. CLINICAL IMPACT: This multicenter study demonstrates that ruptured aortoiliac aneurysms do not necessarily require mandatory occlusion of hypogastric arteries. Iliac branch devices are shown to be a valid alternative in highly selected cases, with good midterm results, even if reinterventions are required in a significant proportion of patients.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Tipo de estudo: Clinical_trials / Risk_factors_studies Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Tipo de estudo: Clinical_trials / Risk_factors_studies Idioma: En Ano de publicação: 2023 Tipo de documento: Article