Your browser doesn't support javascript.
loading
Preparation of Free-Flowing Spray-Dried Amorphous Composites Using Neusilin®.
Lin, Zhixing; Zheng, Kai; Azad, Mohammad A; Davé, Rajesh N.
Afiliação
  • Lin Z; New Jersey Center for Engineered Particulates, New Jersey Institute of Technology, Newark, NJ, 07102, USA.
  • Zheng K; New Jersey Center for Engineered Particulates, New Jersey Institute of Technology, Newark, NJ, 07102, USA.
  • Azad MA; Chemical, Biological and Bioengineering Department, North Carolina A&T State University, Greensboro, NC, 27411, USA.
  • Davé RN; New Jersey Center for Engineered Particulates, New Jersey Institute of Technology, Newark, NJ, 07102, USA. dave@njit.edu.
AAPS PharmSciTech ; 24(1): 51, 2023 Jan 26.
Article em En | MEDLINE | ID: mdl-36703032
ABSTRACT
A highly porous additive, Neusilin®, with high adsorption capability is investigated to improve bulk properties, hence processability of spray-dried amorphous solid dispersions (ASDs). Griseofulvin (GF) is applied as a model BCS class 2 drug in ASDs. Two grades of Neusilin®, US2 (coarser) and UFL2 (finer), were used as additives to produce spray-dried amorphous composite (AC) powders, and their performance was compared with the resulting ASDs without added Neusilin®. The resulting AC powders that included Neusilin® had greatly enhanced flowability (flow function coefficient (FFC) > 10) comparable to larger particles (100 µm) yet had finer particle size (< 50 µm), hence retaining the advantage of fast dissolution rate of finer sizes. Dissolution results demonstrated that achieved GF supersaturation for AC powders with Neusilin® was as high as 3 times that of crystalline GF concentration and was achieved within 30 min. In addition, 80% of drug was released within 4 min. The flowability improvement for AC powders with Neusilin® was more significant as compared to spray-dried ASDs without Neusilin®. Thus, the role of Neusilin® in flowability improvement was evident, considering that spray-dried AC with Neusilin® UFL2 has higher FFC than ASDs having a similar size. Lastly, the AC powders retained a fully amorphous state of GF after 3-month ambient storage. The overall results conveyed that the improved flowability and dissolution rate could outweigh the loss of drug loading resulted by addition of Neusilin®.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Solubilidade Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Solubilidade Idioma: En Ano de publicação: 2023 Tipo de documento: Article