Your browser doesn't support javascript.
loading
Treatment Outcome Comparison Between two 3-Dimensional Plates (Y-Shaped Plate Versus Trapezoidal Condylar Plate) in Management of Mandible Condylar Fracture: A Randomized Control Trial.
Kumar, Shailendra; Chugh, Ankita; Kaur, Amanjot; G, Aparna; Srivastav, Shival; P G, Gigi; Kumar, Pravin; Chaudhry, Kirti.
Afiliação
  • Kumar S; Oral and Maxillofacial Surgery, Department of Dentistry, All India Institute of Medical Sciences, Jodhpur, Rajasthan 342005 India.
  • Chugh A; Oral and Maxillofacial Surgery, Department of Dentistry, All India Institute of Medical Sciences, Jodhpur, Rajasthan 342005 India.
  • Kaur A; Oral and Maxillofacial Surgery, Department of Dentistry, All India Institute of Medical Sciences, Jodhpur, Rajasthan 342005 India.
  • G A; Oral and Maxillofacial Surgery, Department of Dentistry, All India Institute of Medical Sciences, Jodhpur, Rajasthan 342005 India.
  • Srivastav S; Department of Physiology, All India Institute of Medical Sciences, Jodhpur, Rajasthan 342005 India.
  • P G G; Oral and Maxillofacial Surgery, Department of Dentistry, All India Institute of Medical Sciences, Jodhpur, Rajasthan 342005 India.
  • Kumar P; Department of Dentistry, All India Institute of Medical Sciences, Jodhpur, Rajasthan 342005 India.
  • Chaudhry K; Oral and Maxillofacial Surgery, Department of Dentistry, All India Institute of Medical Sciences, Jodhpur, Rajasthan 342005 India.
J Maxillofac Oral Surg ; 22(1): 25-32, 2023 Mar.
Article em En | MEDLINE | ID: mdl-36703652
ABSTRACT

Aim:

To compare the treatment outcomes (clinical, functional and radiographical) using the two different 3-Dimensional plates in open reduction internal fixation of mandibular condylar fracture (MCF). Assessment of ease of fixation and fixation time were also performed.

Methodology:

20 MCF patients were divided equally into two groups (Group A Trapezoidal Condylar Plate and Group B Y-shaped plate) and the treatment outcomes were compared. Intraoperatively time required for fixation was also compared. The patients were followed up at different timelines till 3 months.

Result:

Baseline parameters had statistically insignificant distribution in both groups implying effective randomization and balanced confounding factors. Intraoperatively, adequate anatomical reduction was achieved in both groups with statistically insignificant difference in time required for fixation. Postoperatively, no statistically significant difference was found in radiographic and functional parameters. None of the patients in either group reported with facial nerve injury, condylar resorption, Temporomandibular Disorders. However, 02 patients in Group A and 01 patient in Group B presented with infection, parotid fistula, and hardware failure respectively with statistically insignificant difference.

Conclusion:

This study concluded that the treatment outcomes were satisfactory with the use of both 3-D plate, but further studies with larger sample size and longer follow up are required.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Tipo de estudo: Clinical_trials Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Tipo de estudo: Clinical_trials Idioma: En Ano de publicação: 2023 Tipo de documento: Article