Your browser doesn't support javascript.
loading
[Research on early warning model of the hearing loss of workers exposed to noise].
Qi, H H; Du, Y Y; Tian, Y; Wang, Y W; Quan, L M; Zhou, D L.
Afiliação
  • Qi HH; West China School of Public Health and West China Fourth Hospital, Sichuan University, Chengdu 610041, China.
  • Du YY; West China School of Public Health and West China Fourth Hospital, Sichuan University, Chengdu 610041, China.
  • Tian Y; West China School of Public Health and West China Fourth Hospital, Sichuan University, Chengdu 610041, China.
  • Wang YW; West China School of Public Health and West China Fourth Hospital, Sichuan University, Chengdu 610041, China.
  • Quan LM; West China School of Public Health and West China Fourth Hospital, Sichuan University, Chengdu 610041, China.
  • Zhou DL; West China School of Public Health and West China Fourth Hospital, Sichuan University, Chengdu 610041, China.
Article em Zh | MEDLINE | ID: mdl-36725295
ABSTRACT

Objective:

To explore the change of hearing threshold of workers exposed to noise, establish an individual-based hearing loss early warning model, accurately and differentiated the health of workers exposed to noise.

Methods:

In September 2019, all physical examination data of 561 workers exposed to noise from an enterprise were collected since their employment. Three indicators of average hearing threshold of the better ear, namely, at high frequency, 4000 Hz and speech frequency, were constructed. The generalized estimating equation (GEE) was used to adjust gender and age and establish the warning model of each indicator. Finally, sensitive indicators and warning models were screened according to AUC and Yoden index.

Results:

Among the 561 workers exposed to noise, 26 (4.6%) workers had hearing loss. The sensitivity indicators were the average hearing threshold at speech frequency ≥20 dB, high frequency ≥30 dB and 4000 Hz ≥25 dB. The AUC of each index was 0.602, 0.794 and 0.804, and the Youden indexes were 0.204, 0.588 and 0.608, respectively. In GEE of hearing loss warning models, high-frequency hearing threshold ≥20 dB and 4000 Hz hearing threshold ≥25 dB were the optimal models, with AUC of 0.862.

Conclusion:

Combined with the changes of individual hearing threshold over the years, can accurately assess the risk of individual hearing loss of workers exposed to noise.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Exposição Ocupacional / Surdez / Perda Auditiva Provocada por Ruído / Ruído Ocupacional / Doenças Profissionais Tipo de estudo: Diagnostic_studies / Etiology_studies / Prognostic_studies Limite: Humans Idioma: Zh Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Exposição Ocupacional / Surdez / Perda Auditiva Provocada por Ruído / Ruído Ocupacional / Doenças Profissionais Tipo de estudo: Diagnostic_studies / Etiology_studies / Prognostic_studies Limite: Humans Idioma: Zh Ano de publicação: 2023 Tipo de documento: Article