Your browser doesn't support javascript.
loading
Extra-axonal contribution to double diffusion encoding-based pore size estimates in the corticospinal tract.
Ulloa, Patricia; Methot, Vincent; Wottschel, Viktor; Koch, Martin A.
Afiliação
  • Ulloa P; Institute of Medical Engineering, University of Luebeck, Ratzeburger Allee 160, 23562, Luebeck, Germany. pat.ulloaalmendras@uni-luebeck.de.
  • Methot V; Institute of Medical Engineering, University of Luebeck, Ratzeburger Allee 160, 23562, Luebeck, Germany.
  • Wottschel V; Department of Radiology and Nuclear Medicine, Amsterdam University Medical Centers, De Boelelaan 1117, 1081, Amsterdam, The Netherlands.
  • Koch MA; Institute of Medical Engineering, University of Luebeck, Ratzeburger Allee 160, 23562, Luebeck, Germany.
MAGMA ; 36(4): 589-612, 2023 Aug.
Article em En | MEDLINE | ID: mdl-36745290
ABSTRACT

OBJECTIVE:

To study the origin of compartment size overestimation in double diffusion encoding MRI (DDE) in vivo experiments in the human corticospinal tract. Here, the extracellular space is hypothesized to be the origin of the DDE signal. By exploiting the DDE sensitivity to pore shape, it could be possible to identify the origin of the measured signal. The signal difference between parallel and perpendicular diffusion gradient orientation can indicate if a compartment is regular or eccentric in shape. As extracellular space can be considered an eccentric compartment, a positive difference would mean a high contribution to the compartment size estimates. MATERIALS AND

METHODS:

Computer simulations using MISST and in vivo experiments in eight healthy volunteers were performed. DDE experiments using a double spin-echo preparation with eight perpendicular directions were measured in vivo. The difference between parallel and perpendicular gradient orientations was analyzed using a Wilcoxon signed-rank test and a Mann-Whitney U test.

RESULTS:

Simulations and MR experiments showed a statistically significant difference between parallel and perpendicular diffusion gradient orientation signals ([Formula see text]).

CONCLUSION:

The results suggest that the DDE-based size estimate may be considerably influenced by the extra-axonal compartment. However, the experimental results are also consistent with purely intra-axonal contributions in combination with a large fiber orientation dispersion.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Tratos Piramidais / Imagem de Difusão por Ressonância Magnética Limite: Humans Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Tratos Piramidais / Imagem de Difusão por Ressonância Magnética Limite: Humans Idioma: En Ano de publicação: 2023 Tipo de documento: Article