Your browser doesn't support javascript.
loading
Evaluation of cannulated compression headless screws as an alternative implant for superior pubic ramus fracture fixation: a biomechanical study.
Berk, Till; Zderic, Ivan; Schwarzenberg, Peter; Pastor, Tatjana; Lesche, Felix; Halvachizadeh, Sascha; Richards, R Geoff; Gueorguiev, Boyko; Pape, Hans-Christoph.
Afiliação
  • Berk T; AO Research Institute Davos, Clavadelerstrasse 8, 7270, Davos, Switzerland. Till.Berk@usz.ch.
  • Zderic I; Department of Trauma, University Hospital Zurich, Raemistrasse 100, 8091, Zurich, Switzerland. Till.Berk@usz.ch.
  • Schwarzenberg P; AO Research Institute Davos, Clavadelerstrasse 8, 7270, Davos, Switzerland.
  • Pastor T; AO Research Institute Davos, Clavadelerstrasse 8, 7270, Davos, Switzerland.
  • Lesche F; AO Research Institute Davos, Clavadelerstrasse 8, 7270, Davos, Switzerland.
  • Halvachizadeh S; Department of Plastic and Hand Surgery, Inselspital University Hospital Bern, University of Bern, Bern, Switzerland.
  • Richards RG; Department of Gynecology and Obstetrics, Asklepios Clinic Wandsbek, Alphonsstraße 14, 22043, Hamburg, Germany.
  • Gueorguiev B; Department of Trauma, University Hospital Zurich, Raemistrasse 100, 8091, Zurich, Switzerland.
  • Pape HC; University of Zurich, Harald-Tscherne Laboratory for Orthopedic and Trauma Research, Sternwartstrasse 14, 8091, Zurich, Switzerland.
Int Orthop ; 47(4): 1079-1087, 2023 04.
Article em En | MEDLINE | ID: mdl-36749374
ABSTRACT
BACKGROUND/

PURPOSE:

Pubic ramus fractures account for the most common types of pelvic fractures. The standard surgical approach for superior pubic ramus fractures (SPRF) is a minimally invasive percutaneous screw fixation. However, percutaneous closed reduction and internal fixation of anterior pelvic ring injuries have high failure rates of up to 15%. The aim of this biomechanical study was to evaluate the stability of SPRF following stabilization with retrograde placed cannulated compression headless screw (CCHS) versus conventional fully and partially threaded screws in an artificial pelvic bone model.

METHODS:

SPRF type II as described by Nakatani et al. was created by means of osteotomies in eighteen anatomical composite hemi-pelvises. Specimens were stratified into three groups of six specimens each (n = 6) for fixation with either a 7.3 mm partially threaded cannulated screw (group RST), a 7.3 mm fully threaded cannulated screw (group RSV), or a 7.5 mm partially threaded cannulated CCHS (group CCS). Each hemi-pelvic specimen was tested in an inverted upright standing position under progressively increasing cyclic axial loading. The peak load, starting at 200 N, was monotonically increased at a rate of 0.1 N/cycle until 10 mm actuator displacement.

RESULTS:

Total and torsional displacement were associated with higher values for RST versus CCS and RSV, with significant differences between RST and CCS for both these parameters (p ≤ 0.033). The differences between RST and RSV were significant for total displacement (p = 0.020), and a trend toward significance for torsional displacement (p = 0.061) was observed. For both failure criteria 2 mm total displacement and 5° torsional displacement, CCS was associated with significantly higher number of cycles compared to RST (p ≤ 0.040).

CONCLUSION:

CCHS fixation presented predominantly superior stability to the standard surgical treatment and could therefore be a possible alternative implant for retrograde SPRF screw fixation, whereas partially threaded screws in group RST were associated with inferior biomechanical stability.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Ossos Pélvicos / Fraturas Ósseas Tipo de estudo: Prognostic_studies Limite: Humans Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Ossos Pélvicos / Fraturas Ósseas Tipo de estudo: Prognostic_studies Limite: Humans Idioma: En Ano de publicação: 2023 Tipo de documento: Article