Transparent Cross-Flow Platform as Chemiluminescence Detection Cell in Cross Injection Analysis.
Somboonsuk, Thachkorn; Saetear, Phoonthawee; Mantim, Thitirat; Ratanawimarnwong, Nuanlaor; Wilairat, Prapin; Choengchan, Nathawut; Nacapricha, Duangjai.
Afiliação
  • Somboonsuk T; Flow Innovation-Research for Science and Technology Laboratories (Firstlabs), Ratchathewi District, Bangkok 10110, Thailand.
  • Saetear P; Department of Chemistry and Center of Excellence for Innovation in Chemistry, Faculty of Science, Mahidol University, Rama 6 Road, Ratchathewi District, Bangkok 10400, Thailand.
  • Mantim T; Flow Innovation-Research for Science and Technology Laboratories (Firstlabs), Ratchathewi District, Bangkok 10110, Thailand.
  • Ratanawimarnwong N; Department of Chemistry and Center of Excellence for Innovation in Chemistry, Faculty of Science, Mahidol University, Rama 6 Road, Ratchathewi District, Bangkok 10400, Thailand.
  • Wilairat P; Flow Innovation-Research for Science and Technology Laboratories (Firstlabs), Ratchathewi District, Bangkok 10110, Thailand.
  • Choengchan N; Department of Chemistry, Faculty of Science, Srinakharinwirot University, Sukhumvit 23, Watthana District, Bangkok 10110, Thailand.
  • Nacapricha D; Flow Innovation-Research for Science and Technology Laboratories (Firstlabs), Ratchathewi District, Bangkok 10110, Thailand.
Molecules ; 28(3)2023 Jan 30.
Article em En | MEDLINE | ID: mdl-36770983
ABSTRACT
This work presents the use of a transparent 'Cross Injection Analysis' (CIA) platform as a flow system for chemiluminescence (CL) measurements. The CL-CIA flow device incorporates introduction channels for samples and reagents, and the reaction and detection channels are in one acrylic unit. A photomultiplier tube placed above the reaction channel detects the emitted luminescence. The system was applied to the analysis of (i) Co(II) via the Co(II)-catalyzed H2O2-luminol reaction and (ii) paracetamol via its inhibitory effect on the catalytic activity of Fe(CN)63- on the H2O2-luminol reaction. A linear calibration was obtained for Co(II) in the range of 0.002 to 0.025 mg L-1 Co(II) (r2 = 0.9977) for the determination of Co(II) in water samples. The linear calibration obtained for the paracetamol was 10 to 200 mg L-1 (r2 = 0.9906) for the determination of pharmaceutical products. The sample throughput was 60 samples h-1. The precision was ≤4.2% RSD. The consumption of the samples and reagents was ca. 170 µL per analysis cycle.