Your browser doesn't support javascript.
loading
Human plasma ricinine quantification by LC-HRMS after micro-solid-phase elution.
Thiebot, Pauline; Maaziz, Nada; Oppon, Chrystelle; Bertolo, Laetitia; Magny, Romain; Chevillard, Lucie; Mégarbane, Bruno; Houzé, Pascal; Labat, Laurence.
Afiliação
  • Thiebot P; Laboratoire de Toxicologie Biologique, Fédération de Toxicologie, Hôpital Lariboisière, APHP, Paris, France.
  • Maaziz N; INSERM UMRS-1144, Université Paris Cité, Paris, France.
  • Oppon C; Laboratoire de Toxicologie Biologique, Fédération de Toxicologie, Hôpital Lariboisière, APHP, Paris, France.
  • Bertolo L; Laboratoire de Toxicologie Biologique, Fédération de Toxicologie, Hôpital Lariboisière, APHP, Paris, France.
  • Magny R; Laboratoire de Toxicologie Biologique, Fédération de Toxicologie, Hôpital Lariboisière, APHP, Paris, France.
  • Chevillard L; Laboratoire de Toxicologie Biologique, Fédération de Toxicologie, Hôpital Lariboisière, APHP, Paris, France.
  • Mégarbane B; INSERM UMRS-1144, Université Paris Cité, Paris, France.
  • Houzé P; INSERM UMRS-1144, Université Paris Cité, Paris, France.
  • Labat L; INSERM UMRS-1144, Université Paris Cité, Paris, France.
Biomed Chromatogr ; 37(5): e5604, 2023 May.
Article em En | MEDLINE | ID: mdl-36776032
A rapid, sensitive and specific method for ricinine identification and quantification in plasma has been developed by LC-HRMS. Deuterated ricinine was used as the internal standard. From 100 µL of plasma, ricinine was extracted using micro-solid-phase elution, which allows a reduced extraction time, by eliminating the evaporation step. Eluate is directly injected into the LC-HRMS system. Chromatographic separation was performed using a reverse-phase C18 column with a 4.5 min gradient elution. The method was validated according to European Medicines Agency guidelines. Linearity was verified between 0.25 and 500.0 ng/mL; the maximum precision calculated was 19.9% for the lower limit of quantitation and 9.6% for quality control, and accuracy was within ± 5.6% of the nominal concentrations. Selectivity, carryover, matrix effect and stability were also verified according to European Medicines Agency guidelines. The method allows the rapid and reliable identification of ricin-exposed victims in case of terrorist attacks or poisonings: three intoxication cases are reported.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Alcaloides Tipo de estudo: Prognostic_studies Limite: Humans Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Alcaloides Tipo de estudo: Prognostic_studies Limite: Humans Idioma: En Ano de publicação: 2023 Tipo de documento: Article