Your browser doesn't support javascript.
loading
Multi-objective optimization of hydrant flushing in a water distribution system using a fast hybrid technique.
Shoorangiz, Mostafa; Nikoo, Mohammad Reza; Simunek, Jirka; Gandomi, Amir H; Adamowski, Jan Franklin; Al-Wardy, Malik.
Afiliação
  • Shoorangiz M; Department of Civil and Environmental Engineering, Shiraz University, Shiraz, Iran. Electronic address: mosishoorangiz@gmail.com.
  • Nikoo MR; Department of Civil and Architectural Engineering, Sultan Qaboos University, Muscat, Oman. Electronic address: m.reza@squ.edu.om.
  • Simunek J; Department of Environmental Sciences, University of California, Riverside, USA. Electronic address: jiri.simunek@ucr.edu.
  • Gandomi AH; Faculty of Engineering & IT, University of Technology Sydney, Sydney, NSW, Australia; University Research and Innovation Center (EKIK), Óbuda University, 1034, Budapest, Hungary. Electronic address: gandomi@uts.edu.au.
  • Adamowski JF; Department of Bioresource Engineering, McGill University, QC, Canada. Electronic address: jan.adamowski@mcgill.ca.
  • Al-Wardy M; Department of Soils, Water and Agricultural Engineering, Sultan Qaboos University, Muscat, Oman. Electronic address: mwardy@squ.edu.om.
J Environ Manage ; 334: 117463, 2023 May 15.
Article em En | MEDLINE | ID: mdl-36801802
ABSTRACT
As a critical element in preserving the health of urban populations, water distribution systems (WDSs) must be ready to implement emergency plans when catastrophic events such as contamination events occur. A risk-based simulation-optimization framework (EPANET-NSGA-III) combined with a decision support model (GMCR) is proposed in this study to determine optimal locations for contaminant flushing hydrants under an array of potentially hazardous scenarios. Risk-based analysis using Conditional Value-at-Risk (CVaR)-based objectives can address uncertainties regarding the mode of WDS contamination, thereby providing a robust plan to minimize the associated risks at a 95% confidence level. Conflict modeling by GMCR achieved an optimal compromise solution within the Pareto front by identifying a final stable consensus among the decision-makers involved. A novel hybrid contamination event grouping-parallel water quality simulation technique was incorporated into the integrated model to reduce model runtime, the main deterrent in optimization-based methods. The nearly 80% reduction in model runtime made the proposed model a viable solution for online simulation-optimization problems. The framework's capacity to address real-world problems was evaluated for the WDS operating in Lamerd, a city in Fars Province, Iran. Results showed that the proposed framework was capable of highlighting a single flushing strategy, which not only optimally reduced risks associated with contamination events, but provided acceptable coverage against such threats, flushing 35-61.3% of input contamination mass on average, and reducing average time-to-return to normal conditions by 14.4-60.2%, while employing less than half of the initial potential hydrants.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Poluição da Água / Abastecimento de Água / Simulação por Computador Tipo de estudo: Prognostic_studies País como assunto: Asia Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Poluição da Água / Abastecimento de Água / Simulação por Computador Tipo de estudo: Prognostic_studies País como assunto: Asia Idioma: En Ano de publicação: 2023 Tipo de documento: Article