Your browser doesn't support javascript.
loading
Contact force and catheter stability are predictive metrics of successful pulmonary vein isolation with high-power short duration ablation in atrial fibrillation.
Honarbakhsh, Shohreh; Martin, Claire A; Dhillon, Gurpreet; Gallagher, Mark; Sohal, Manav; Chow, Anthony; Ahsan, Syed; Abbass, Hakam; Whittaker-Axon, Sarah; Lambiase, Pier D; Davies, Mark J; Ginks, Matthew; Hunter, Ross J.
Afiliação
  • Honarbakhsh S; The Barts Heart Centre, St Bartholomew's Hospital, Barts Health NHS Trust, London, UK.
  • Martin CA; William Harvey Research Institute, Queen Mary's University of London, London, UK.
  • Dhillon G; Royal Papworth Hospital, Cambridge, UK.
  • Gallagher M; St George's University Hospitals NHS Foundation Trust, London, UK.
  • Sohal M; St George's University Hospitals NHS Foundation Trust, London, UK.
  • Chow A; St George's University Hospitals NHS Foundation Trust, London, UK.
  • Ahsan S; The Barts Heart Centre, St Bartholomew's Hospital, Barts Health NHS Trust, London, UK.
  • Abbass H; The Barts Heart Centre, St Bartholomew's Hospital, Barts Health NHS Trust, London, UK.
  • Whittaker-Axon S; The Barts Heart Centre, St Bartholomew's Hospital, Barts Health NHS Trust, London, UK.
  • Lambiase PD; The Barts Heart Centre, St Bartholomew's Hospital, Barts Health NHS Trust, London, UK.
  • Davies MJ; The Barts Heart Centre, St Bartholomew's Hospital, Barts Health NHS Trust, London, UK.
  • Ginks M; Oxford University Hospitals NHS Foundation Trust, Oxford, UK.
  • Hunter RJ; Oxford University Hospitals NHS Foundation Trust, Oxford, UK.
J Cardiovasc Electrophysiol ; 34(5): 1141-1151, 2023 05.
Article em En | MEDLINE | ID: mdl-36808788
ABSTRACT

INTRODUCTION:

Preliminary data suggest that high power short duration (HPSD) ablation for pulmonary vein isolation (PVI) are safe. Limited data are available on its effectiveness. Aim was to evaluate HPSD ablation in atrial fibrillation ablation using a novel Qdot Micro catheter. METHODS AND

RESULTS:

Prospective multicenter study evaluating safety and efficacy of PVI with HPSD ablation. First pass isolation (FPI) and sustained PVI was assessed. If FPI was not achieved additional ablation index (AI)-guided ablation with 45 W was performed and metrics predictive of this were determined. Sixty-five patients and 260 veins were treated. Procedural and LA dwell time was 93.9 ± 30.4 and 60.5 ± 23.1 min, respectively. FPI was achieved in 47 (72.3%) patients and 231 veins (88.8%) with an ablation duration of 4.6 ± 1.0 min. Twenty-nine veins required additional AI-guided ablation to achieve initial PVI with 24 anatomical sites ablated with the right posterior carina being the most common site (37.5%). A contact force of ≥8 g (area under the curve [AUC] 0.81; p < 0.001) and catheter position variation of ≤1.2 mm (AUC 0.79; p < 0.001) with HPSD were strongly predictive of not requiring additional AI-guided ablation. Out of the 260 veins, only 5 (1.9%) veins showed acute reconnection. HPSD ablation was associated with shorter procedure times (93.9 vs. 159.4 min; p < 0.001), ablation times (6.1 vs. 27.7 min; p < 0.001), and lower rates of PV reconnection (9.2% vs. 30.8%; p = 0.004) compared to moderate power cohort.

CONCLUSIONS:

HPSD ablation is an effective ablation modality which results in effective PVI whilst maintaining a safety profile. Its superiority needs to be evaluated in randomized controlled trials.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Veias Pulmonares / Fibrilação Atrial / Ablação por Cateter Tipo de estudo: Clinical_trials / Diagnostic_studies / Etiology_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Humans Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Veias Pulmonares / Fibrilação Atrial / Ablação por Cateter Tipo de estudo: Clinical_trials / Diagnostic_studies / Etiology_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Humans Idioma: En Ano de publicação: 2023 Tipo de documento: Article