Your browser doesn't support javascript.
loading
Midterm results on a new self-expandable covered stent combined with branched stent grafts: Insights from a multicenter Italian registry.
Bertoglio, Luca; Grandi, Alessandro; Veraldi, Gian Franco; Pulli, Raffaele; Antonello, Michele; Bonvini, Stefano; Isernia, Giacomo; Bellosta, Raffaello; Buia, Francesco; Silingardi, Roberto.
Afiliação
  • Bertoglio L; Division of vascular Surgery, Vita-Salute San Raffaele University, IRCCS San Raffaele Scientific Institute, Milan, Italy. Electronic address: luca.bertoglio@unibs.it.
  • Grandi A; Division of vascular Surgery, Vita-Salute San Raffaele University, IRCCS San Raffaele Scientific Institute, Milan, Italy.
  • Veraldi GF; Division Vascular Surgery, Integrated University Hospital of Verona, Verona, Italy.
  • Pulli R; Division Vascular Surgery, Department of Cardiothoracic Surgery, University of Bari School of Medicine, Bari, Italy.
  • Antonello M; Vascular and Endovascular Surgery Unit, Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padua, Padua, Italy.
  • Bonvini S; Department of Vascular Surgery, Santa Chiara Hospital, Trento, Italy.
  • Isernia G; Unit of Vascular and Endovascular Surgery, Santa Maria della Misericordia Hospital, Perugia, Italy.
  • Bellosta R; Division of vascular Surgery, Cardiovascular Department, Poliambulanza Foundation, Brescia, Italy.
  • Buia F; Pediatric and Adult Cardio-Thoracovascular, Onchoematologic and Emergencies Radiology Unit, IRCCS Azienda Ospedaliero-Universitaria di Bologna, Bologna, Italy.
  • Silingardi R; Division of vascular Surgery, Ospedale Civile di Baggiovara, Azienda Ospedaliero-Universitaria di Modena, University of Modena and Reggio Emilia, Modena, Italy.
J Vasc Surg ; 77(6): 1598-1606.e3, 2023 06.
Article em En | MEDLINE | ID: mdl-36822256
ABSTRACT

OBJECTIVE:

To investigate the technical periprocedural and midterm outcomes of endovascular repairs with multibranched endovascular repair or iliac branch devices combined with a new self-expanding covered stent.

METHODS:

The COvera in BRAnch registry is a physician-initiated, multicenter, ambispective, observational registry (ClinicalTrials.gov Identifier NCT04598802) enrolling patients receiving a multibranched endovascular repair or iliac branch devices procedure mated with Bard Covera Plus (Tempe, AZ) covered stent, designed to evaluate the outcomes of the covered stent mated with patient-specific and off-the-shelf branched stent graft. Primary end points were technical success, branch instability, and freedom from aortic and branch-related reintervention within 30 days and at follow-up. Preoperative characteristics, comorbidities, and outcomes definitions were graded according to the Society for Vascular Surgery reporting standards.

RESULTS:

Two hundred eighty-four patients (76 years; range, 70-80 years; 79% males) in 24 centers were enrolled for a total of 708 target vessels treated. The covered stents were mated with an off-the-shelf graft in 556 vessels (79%) and a custom-made graft in 152 (21%). Three hundred seven adjunctive relining stents in 277 vessels (39%) were deployed, of which 116 (38%) were proximal, 66 (21%) intrastent, and 125 (41%) distal. Adjunctive relining stent placement was more frequent when landing in a vessel branch instead of the main trunk (59% vs 39%; P = .031), performing a percutaneous access (49% vs 35%; P < .001), using a stent with a diameter of 8 mm or greater (44% vs 36%; P = .032) and a length of 80 mm or greater (65% vs 55%; P = .005), when a post-dilatation was not performed (45% vs 29%; P < .001) and when an inner branch configuration was used (55% vs 35%; P < .001). Perioperative technical bridging success was 98%. Eight patients (3%) died in the perioperative period. Two deaths (1%) were associated with renal branch occlusion followed by acute kidney injury and paraplegia. Follow-up data were available for 638 vessels (90%) at a median of 32 months (Q1, Q3, 21, 46). Branch instability was reported in 1% of branches. Forty-six patients (17%) died during follow-up, nine (3%) of them owing to aortic-related causes. Primary patency rates at 1, 2, and 3 years were 99% (581/587), 99% (404/411), and 97% (272/279), respectively. Branch instability was associated with patient-specific devices (9% vs 4%; P = .014) and intrastent adjunctive stent placement (12% vs 2%; P = .003), especially when a bare metal balloon-expandable stent was used (25% vs 3%; P < .001).

CONCLUSIONS:

The use of this new self-expanding covered stent mated with branched endografts proved to be safe and feasible with high technical procedural success rates. Low rates of branch instability were observed at midterm follow-up. Comparative studies with other commercially available covered stents are warranted.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Aneurisma da Aorta Torácica / Implante de Prótese Vascular / Procedimentos Endovasculares Tipo de estudo: Clinical_trials / Etiology_studies / Guideline / Prognostic_studies / Risk_factors_studies Limite: Female / Humans / Male País como assunto: Europa Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Aneurisma da Aorta Torácica / Implante de Prótese Vascular / Procedimentos Endovasculares Tipo de estudo: Clinical_trials / Etiology_studies / Guideline / Prognostic_studies / Risk_factors_studies Limite: Female / Humans / Male País como assunto: Europa Idioma: En Ano de publicação: 2023 Tipo de documento: Article