Your browser doesn't support javascript.
loading
Advances in Digital PET Technology and Its Potential Impact on Myocardial Perfusion and Blood Flow Quantification.
Alahdab, Fares; Al Rifai, Mahmoud; Ahmed, Ahmed Ibrahim; Al-Mallah, Mouaz H.
Afiliação
  • Alahdab F; Houston Methodist DeBakey Heart & Vascular Center, 6550 Fannin Street, Smith Tower - Suite 1801, 77030, Houston, TX, USA.
  • Al Rifai M; Houston Methodist DeBakey Heart & Vascular Center, 6550 Fannin Street, Smith Tower - Suite 1801, 77030, Houston, TX, USA.
  • Ahmed AI; Houston Methodist DeBakey Heart & Vascular Center, 6550 Fannin Street, Smith Tower - Suite 1801, 77030, Houston, TX, USA.
  • Al-Mallah MH; Houston Methodist DeBakey Heart & Vascular Center, 6550 Fannin Street, Smith Tower - Suite 1801, 77030, Houston, TX, USA. mal-mallah@houstonmethodist.org.
Curr Cardiol Rep ; 25(4): 261-268, 2023 04.
Article em En | MEDLINE | ID: mdl-36826688
ABSTRACT
PURPOSE OF REVIEW In this review, we explore the development of digital PET scanners and describe the mechanism by which they work. We dive into some technical details on what differentiates a digital PET from a conventional PET scanner and how such differences lead to better imaging characteristics. Additionally, we summarize the available evidence on the improvements in the images acquired by digital PET as well as the remaining pitfalls. Finally, we report the comparative studies available on how digital PET compares to conventional PET, particularly in the quantification of coronary blood flow. RECENT

FINDINGS:

The advent of digital PET offers high sensitivity and time-of-flight (TOF), which allow lower activity and scan times, with much less risk of detector saturation. This allows faster patient throughput, scanning more patients per generator, and acquiring more consistent image quality across patients. The higher sensitivity captures more of the potential artifacts, particularly motion-related ones, which presents a current challenge that still needs to be tackled. The digital silicon photomultiplier (SiPM) positron emission tomography (PET) machine has been an important development in the technological advancements of non-invasive nuclear cardiovascular imaging. It has enhanced the utility for PET myocardial perfusion imaging (MPI) and myocardial blood flow (MBF) quantification.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Doença da Artéria Coronariana / Imagem de Perfusão do Miocárdio Limite: Humans Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Doença da Artéria Coronariana / Imagem de Perfusão do Miocárdio Limite: Humans Idioma: En Ano de publicação: 2023 Tipo de documento: Article