Your browser doesn't support javascript.
loading
Qualitative and quantitative analysis of an explanted opacified hydrophilic IOL after over two years from cataract surgery.
Tripodi, Sarah; Toro, Mario Damiano; Rejdak, Robert; Costagliola, Ciro; Avitabile, Teresio; Carnevali, Adriano; Bruzzichessi, Donatella; Gambaro, Stefano; Porta, Alessandro.
Afiliação
  • Tripodi S; Department of Ophthalmology, IRCCS Sacro Cuore Don Calabria Hospital, Negrar, Italy.
  • Toro MD; Department of Neurosciences, Reproductive Sciences and Dentistry, University of Naples "Federico II", Naples, Italy.
  • Rejdak R; Department of General and Pediatric Ophthalmology, Medical University of Lublin, Lublin, Poland.
  • Costagliola C; Department of General and Pediatric Ophthalmology, Medical University of Lublin, Lublin, Poland.
  • Avitabile T; Department of Neurosciences, Reproductive Sciences and Dentistry, University of Naples "Federico II", Naples, Italy.
  • Carnevali A; Eye Clinic, University of Catania, Catania, Italy.
  • Bruzzichessi D; Department of Ophthalmology, University Magna Graecia of Catanzaro, Catanzaro, Italy.
  • Gambaro S; Department of Ophthalmology, University Magna Graecia of Catanzaro, Catanzaro, Italy.
  • Porta A; Department of Ophthalmology, Hospital C. Cantù, Abbiategrasso, Italy.
Eur J Ophthalmol ; 33(6): NP28-NP34, 2023 Nov.
Article em En | MEDLINE | ID: mdl-36866563
ABSTRACT
Opacification of hydrophilic intraocular lenses (IOLs) is an uncommon complication, that can appear after uneventful cataract surgery. We report a case of opacified Hydroview® IOL in a 76-year-old woman, with a previous history of pars plana vitrectomy with silicon oil tamponade in her right eye for a proliferative diabetic retinopathy, who developed an opacification of the IOL after over two years from a silicon oil/BSS exchange in combination with an uneventful phacoemulsification. The patient complained about a progressive decrease in her visual acuity. The slit-lamp examination confirmed the opacification of the IOL. Therefore, because of blurred vision, a combined procedure of explant and exchange of the IOL was performed in the same eye. Qualitative (Optic microscope, X-Ray powder Diffraction (XRD), Scanning Electron Microscopy (SEM)) and quantitative (Instrumental Neutron Activation Analysis (INAA)) analysis of the IOL material were performed. Here, our aim is to report the acquired data of the explanted Hydroview® H60M IOL.