Validation of a liquid chromatography-tandem mass spectrometry method for simultaneous quantification of N,N-dimethylacetamide and N-monomethylacetamide in pediatric plasma.
Rosser, Sebastian P A; McLachlan, Andrew J; Hempel, Georg; Chung, Jason; Shaw, Peter J; Keogh, Steven J; Nath, Christa E.
Afiliação
  • Rosser SPA; The Children's Hospital at Westmead Clinical School, University of Sydney, Sydney, Australia.
  • McLachlan AJ; Department of Biochemistry, The Children's Hospital at Westmead, Sydney, Australia.
  • Hempel G; Cancer Centre for Children, The Children's Hospital at Westmead, Sydney, Australia.
  • Chung J; Sydney Pharmacy School, Faculty of Medicine and Health, University of Sydney, Sydney, Australia.
  • Shaw PJ; Institute for Pharmaceutical and Medicinal Chemistry and Clinical Pharmacy, University of Münster, Sydney, Germany.
  • Keogh SJ; The Children's Hospital at Westmead Clinical School, University of Sydney, Sydney, Australia.
  • Nath CE; Department of Biochemistry, The Children's Hospital at Westmead, Sydney, Australia.
J Sep Sci ; 46(10): e2201003, 2023 May.
Article em En | MEDLINE | ID: mdl-36879545
ABSTRACT
N,N-dimethylacetamide is an excipient used in intravenous busulfan formulations, a drug used in hematopoietic stem cell transplantation conditioning. The aim of this study was to develop and validate a liquid chromatography-tandem mass spectrometry method for simultaneous quantification of N,N-dimethylacetamide, and its metabolite N-monomethylacetamide in plasma from children receiving busulfan. A 4 µl aliquot of patient plasma was extracted using 196 µl 50% methanol solution and quantified against calibrators prepared in the extraction solvent given negligible matrix effects across three concentrations. 9 [H2 ]-N,N-dimethylacetamide was used as an internal standard. Separation of N,N-dimethylacetamide and N-monomethylacetamide was achieved using a Kinetex EVO C18 stationary phase (100 mm × 2.1 mm × 2.6 µm) running an isocratic mobile phase of 30% methanol containing 0.1% formic acid at a flow of 0.2 ml/min over 3.0 min. The injection volume was 1 µl. Calibration curves for N,N-dimethylacetamide and N-monomethylacetamide were linear up to 1200 and 200 µg/L, respectively, with a lower limit of quantification 1 µg/L for both analytes. Calibrator accuracy and precision were within ± 10% of the test parameters across four concentration levels. Analytes were stable over 14 days at three different storage conditions. This method was successfully applied to measure N,N-dimethylacetamide and N-monomethylacetamide concentrations in a total of 1265 plasma samples from 77 children.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Bussulfano / Espectrometria de Massas em Tandem Limite: Child / Humans Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Bussulfano / Espectrometria de Massas em Tandem Limite: Child / Humans Idioma: En Ano de publicação: 2023 Tipo de documento: Article