Your browser doesn't support javascript.
loading
Ratiometric Fluorescence Sensing System for Lead Ions Based on Self-Assembly of Bioprobes Triggered by Specific Pb2+-Peptide Interactions.
Mehta, Pramod Kumar; Lee, JaeYoon; Oh, Eun-Taex; Park, Heon Joo; Lee, Keun-Hyeung.
Afiliação
  • Mehta PK; Education and Research Center for Smart Energy Materials and Process, Department of Chemistry and Chemical Engineering, Inha University, Incheon 402-751, South Korea.
  • Lee J; Education and Research Center for Smart Energy Materials and Process, Department of Chemistry and Chemical Engineering, Inha University, Incheon 402-751, South Korea.
  • Oh ET; Department in Biomedical Sciences, College of Medicine, Inha University, Incheon 22212, South Korea.
  • Park HJ; Program in Biomedical Science & Engineering, Inha University, Incheon 22212, South Korea.
  • Lee KH; Education and Research Center for Smart Energy Materials and Process, Department of Chemistry and Chemical Engineering, Inha University, Incheon 402-751, South Korea.
Article em En | MEDLINE | ID: mdl-36883859
ABSTRACT
Lead is one of the most toxic substances. However, there are few ratiometric fluorescent probes for sensing Pb2+ in aqueous solution as well as living cells because specific ligands for Pb2+ ions have not been well characterized. Considering the interactions between Pb2+ and peptides, we developed ratiometric fluorescent probes for Pb2+ based on the peptide receptor in two steps. First, we synthesized fluorescent probes (1-3) based on the tetrapeptide receptor (ECEE-NH2) containing hard and soft ligands by conjugation with diverse fluorophores that showed excimer emission when they aggregated. After investigation of fluorescent responses to metal ions, benzothiazolyl-cyanovinylene was evaluated as an appropriate fluorophore for ratiometric detection of Pb2+. Next, we modified the peptide receptor to decrease the number of hard ligands and/or to replace Cys with disulfide bond and methylated Cys for improving selectivity and cell permeability. From this process, we developed two fluorescent probes (3 and 8) among the probes (1-8) that exhibited remarkable ratiometric sensing properties for Pb2+ including high water solubility (≤2% DMF), visible light excitation, high sensitivity, selectivity for Pb2+, low detection limits (<10 nM), and fast response (<6 min). The binding mode study revealed that specific Pb2+-peptide interactions of the probes caused nanosized aggregates in which the fluorophores of the probes came close each other, exhibiting excimer emission. In particular, 8 based on tetrapeptide bearing a disulfide bond and two carboxyl groups with a good permeability successfully quantified intracellular uptake of Pb2+ in live cells through ratiometric fluorescent signals. The ratiometric sensing system based on specific metal-peptide interactions and excimer emission process could provide a valuable tool to quantify Pb2+ in live cells and pure aqueous solutions.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2023 Tipo de documento: Article