Your browser doesn't support javascript.
loading
Mobile multi-configuration clinical translational Raman system for oral cancer application.
Maryam, Siddra; Konugolu Venkata Sekar, Sanathana; Ghauri, M Daniyal; Fahy, Edward; Nogueira, Marcelo Saito; Lu, Huihui; Beffara, Flavien; Humbert, Georges; Ni Riordain, Richeal; Sheahan, Patrick; Burke, Ray; Wei Kho, Kiang; Gautam, Rekha; Andersson-Engels, Stefan.
Afiliação
  • Maryam S; Tyndall National Institute, University College Cork, Cork, Ireland. siddra.maryam@tyndall.ie.
  • Konugolu Venkata Sekar S; Tyndall National Institute, University College Cork, Cork, Ireland. siddra.maryam@tyndall.ie.
  • Ghauri MD; Tyndall National Institute, University College Cork, Cork, Ireland. siddra.maryam@tyndall.ie.
  • Fahy E; Cork University Dental School and Hospital, Wilton, Cork, Ireland.
  • Nogueira MS; Tyndall National Institute, University College Cork, Cork, Ireland. siddra.maryam@tyndall.ie.
  • Lu H; Tyndall National Institute, University College Cork, Cork, Ireland. siddra.maryam@tyndall.ie.
  • Beffara F; XLIM Research Institute, UMR 7252 CNRS/Limoges University, Limoges, France.
  • Humbert G; XLIM Research Institute, UMR 7252 CNRS/Limoges University, Limoges, France.
  • Ni Riordain R; Cork University Dental School and Hospital, Wilton, Cork, Ireland.
  • Sheahan P; ENTO Research Institute, University College Cork, Cork, Ireland.
  • Burke R; South Infirmary Victoria University Hospital, Cork, Ireland.
  • Wei Kho K; Tyndall National Institute, University College Cork, Cork, Ireland. siddra.maryam@tyndall.ie.
  • Gautam R; Tyndall National Institute, University College Cork, Cork, Ireland. siddra.maryam@tyndall.ie.
  • Andersson-Engels S; Tyndall National Institute, University College Cork, Cork, Ireland. siddra.maryam@tyndall.ie.
Analyst ; 148(7): 1514-1523, 2023 Mar 27.
Article em En | MEDLINE | ID: mdl-36896767
ABSTRACT
Early diagnosis of oral cancer is critical to improve the survival rate of patients. Raman spectroscopy, a non-invasive spectroscopic technique, has shown potential in identifying early-stage oral cancer biomarkers in the oral cavity environment. However, inherently weak signals necessitate highly sensitive detectors, which restricts widespread usage due to high setup costs. In this research, the fabrication and assembly of a customised Raman system that can adapt three different configurations for the in vivo and ex vivo analysis is reported. This novel design will help in reducing the cost required to have multiple Raman instruments specific for a given application. First, we demonstrated the capability of a customized microscope for acquiring Raman signals from a single cell with high signal-to-noise ratio. Generally, when working with liquid samples with low concentration of analytes (such as saliva) under a microscope, excitation light interacts with a small sample volume, which may not be representative of whole sample. To address this issue, we have designed a novel long-path transmission set-up, which was found to be sensitive towards low concentration of analytes in aqueous solution. We further demonstrated that the same Raman system can be incorporated with the multimodal fibre optical probe to collect in vivo data from oral tissues. In summary, this flexible, portable, multi-configuration Raman system has the potential to provide a cost-effective solution for complete screening of precancer oral lesions.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Neoplasias Bucais Tipo de estudo: Diagnostic_studies / Prognostic_studies / Screening_studies Limite: Humans Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Neoplasias Bucais Tipo de estudo: Diagnostic_studies / Prognostic_studies / Screening_studies Limite: Humans Idioma: En Ano de publicação: 2023 Tipo de documento: Article