Your browser doesn't support javascript.
loading
Bimetallic MOF synergy molecularly imprinted ratiometric electrochemical sensor based on MXene decorated with polythionine for ultra-sensitive sensing of catechol.
Lu, Zhiwei; Wei, Kai; Ma, Hao; Duan, Rongtao; Sun, Mengmeng; Zou, Ping; Yin, Jiajian; Wang, Xianxiang; Wang, Yanying; Wu, Chun; Su, Gehong; Wu, Mingjun; Zhou, Xinguang; Ye, Jianshan; Rao, Hanbing.
Afiliação
  • Lu Z; College of Science, Sichuan Agricultural University, Xin Kang Road, Yucheng District, Ya'an, 625014, PR China; Key Laboratory of Pulp and Paper Science & Technology of Ministry of Education, Qilu University of Technology (Shandong Academy of Sciences), Jinan, 250353, PR China. Electronic address
  • Wei K; College of Science, Sichuan Agricultural University, Xin Kang Road, Yucheng District, Ya'an, 625014, PR China.
  • Ma H; Key Laboratory of Pulp and Paper Science & Technology of Ministry of Education, Qilu University of Technology (Shandong Academy of Sciences), Jinan, 250353, PR China.
  • Duan R; College of Science, Sichuan Agricultural University, Xin Kang Road, Yucheng District, Ya'an, 625014, PR China.
  • Sun M; College of Science, Sichuan Agricultural University, Xin Kang Road, Yucheng District, Ya'an, 625014, PR China.
  • Zou P; College of Science, Sichuan Agricultural University, Xin Kang Road, Yucheng District, Ya'an, 625014, PR China.
  • Yin J; College of Science, Sichuan Agricultural University, Xin Kang Road, Yucheng District, Ya'an, 625014, PR China.
  • Wang X; College of Science, Sichuan Agricultural University, Xin Kang Road, Yucheng District, Ya'an, 625014, PR China.
  • Wang Y; College of Science, Sichuan Agricultural University, Xin Kang Road, Yucheng District, Ya'an, 625014, PR China.
  • Wu C; College of Science, Sichuan Agricultural University, Xin Kang Road, Yucheng District, Ya'an, 625014, PR China.
  • Su G; College of Science, Sichuan Agricultural University, Xin Kang Road, Yucheng District, Ya'an, 625014, PR China.
  • Wu M; College of Science, Sichuan Agricultural University, Xin Kang Road, Yucheng District, Ya'an, 625014, PR China.
  • Zhou X; Shenzhen NTEK Testing Technology Co., Ltd., Shenzhen, 518000, Guangdong, PR China.
  • Ye J; School of Chemistry and Chemical Engineering, South China University of Technology, Guangzhou, 510641, PR China. Electronic address: jsye@scut.edu.cn.
  • Rao H; College of Science, Sichuan Agricultural University, Xin Kang Road, Yucheng District, Ya'an, 625014, PR China. Electronic address: rhb@sicau.edu.cn.
Anal Chim Acta ; 1251: 340983, 2023 Apr 22.
Article em En | MEDLINE | ID: mdl-36925281
ABSTRACT
Dual-signal ratiometric molecularly imprinted polymer (MIP) electrochemical sensors with bimetallic active sites and high-efficiency catalytic activity were fabricated for the sensing of catechol (CC) with high selectivity and sensitivity. The amino-functionalization bimetallic organic framework materials (Fe@Ti-MOF-NH2), coupled with two-dimensional layered titanium carbide (MXene) co-modified glassy carbon electrode provides an expanded surface while amplifying the output signal through the electropolymerization immobilization of polythionine (pTHi) and MIP. The oxidation of CC and pTHi were presented as the response signal and the internal reference signal. The oxidation peak current at +0.42 V rose with increased concentration of CC, while the peak currents of pTHi at -0.20 V remained constant. Compared to the common single-signal sensing system, this one (MIP/pTHi/MXene/Fe@Ti-MOF-NH2/GCE), a novel ratiometric MIP electrochemical sensor exhibited two segments wide dynamic range of 1.0-300 µM (R2 = 0.9924) and 300-4000 µM (R2 = 0.9912), as well as an ultralow detection limit of 0.54 µM (S/N = 3). Due to the specific recognition function of MIPs and the advantages of built-in correction of pTHi, the prepared surface imprinting sensor presented an excellent performance in selectivity and reproducibility. Besides, this sensor possessed superior anti-interference ability with ions and biomolecules, excellent reproducibility, repeatability, and acceptable stability. Furthermore, the proposed sensing system exhibits high specific recognition in the determination of environmental matrices and biological fluids in real samples with satisfactory results. Therefore, this signal-enhanced ratiometric MIP electrochemical sensing strategy can accurately and selectively analyze and detect other substances.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Impressão Molecular Tipo de estudo: Diagnostic_studies Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Impressão Molecular Tipo de estudo: Diagnostic_studies Idioma: En Ano de publicação: 2023 Tipo de documento: Article