Your browser doesn't support javascript.
loading
A sub-ppbv-level Acetone and Ethanol Quantum Cascade Laser Based Photoacoustic Sensor - Characterization and Multi-Component Spectra Recording in Synthetic Breath.
Pangerl, Jonas; Moser, Elisabeth; Müller, Max; Weigl, Stefan; Jobst, Simon; Rück, Thomas; Bierl, Rudolf; Matysik, Frank-Michael.
Afiliação
  • Pangerl J; Sensorik-ApplikationsZentrum (SappZ), Regensburg University of Applied Sciences, 93053 Regensburg, Germany.
  • Moser E; Institute of Analytical Chemistry, Chemo, and Biosensors, University of Regensburg, 93053 Regensburg, Germany.
  • Müller M; Sensorik-ApplikationsZentrum (SappZ), Regensburg University of Applied Sciences, 93053 Regensburg, Germany.
  • Weigl S; Faculty of Informatics, Technical University of Munich, 85748 Garching, Germany.
  • Jobst S; Sensorik-ApplikationsZentrum (SappZ), Regensburg University of Applied Sciences, 93053 Regensburg, Germany.
  • Rück T; Institute of Analytical Chemistry, Chemo, and Biosensors, University of Regensburg, 93053 Regensburg, Germany.
  • Bierl R; Sensorik-ApplikationsZentrum (SappZ), Regensburg University of Applied Sciences, 93053 Regensburg, Germany.
  • Matysik FM; Sensorik-ApplikationsZentrum (SappZ), Regensburg University of Applied Sciences, 93053 Regensburg, Germany.
Photoacoustics ; 30: 100473, 2023 Apr.
Article em En | MEDLINE | ID: mdl-36970564
ABSTRACT
Trace gas analysis in breath is challenging due to the vast number of different components. We present a highly sensitive quantum cascade laser based photoacoustic setup for breath analysis. Scanning the range between 8263 and 8270 nm with a spectral resolution of 48 pm, we are able to quantify acetone and ethanol within a typical breath matrix containing water and CO2. We photoacoustically acquired spectra within this region of mid-infra-red light and prove that those spectra do not suffer from non-spectral interferences. The purely additive behavior of a breath sample spectrum was verified by comparing it with the independently acquired single component spectra using Pearson and Spearman correlation coefficients. A previously presented simulation approach is improved and an error attribution study is presented. With a 3σ detection limit of 6.5 ppbv in terms of ethanol and 250 pptv regarding acetone, our system is among the best performing presented so far.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2023 Tipo de documento: Article