Your browser doesn't support javascript.
loading
Impact of radiation dose reduction and iterative image reconstruction on CT-guided spine biopsies.
Paprottka, Karolin J; Kupfer, Karina; Schultz, Vivian; Beer, Meinrad; Zimmer, Claus; Baum, Thomas; Kirschke, Jan S; Sollmann, Nico.
Afiliação
  • Paprottka KJ; Department of Diagnostic and Interventional Neuroradiology, School of Medicine, Klinikum rechts der Isar, Technical University of Munich, Munich, Germany. Karolin.Paprottka@tum.de.
  • Kupfer K; Department of Diagnostic and Interventional Neuroradiology, School of Medicine, Klinikum rechts der Isar, Technical University of Munich, Munich, Germany.
  • Schultz V; Department of Diagnostic and Interventional Neuroradiology, School of Medicine, Klinikum rechts der Isar, Technical University of Munich, Munich, Germany.
  • Beer M; Department of Diagnostic and Interventional Radiology, University Hospital Ulm, Ulm, Germany.
  • Zimmer C; Department of Diagnostic and Interventional Neuroradiology, School of Medicine, Klinikum rechts der Isar, Technical University of Munich, Munich, Germany.
  • Baum T; TUM-Neuroimaging Center, Klinikum rechts der Isar, Technical University of Munich, Munich, Germany.
  • Kirschke JS; Department of Diagnostic and Interventional Neuroradiology, School of Medicine, Klinikum rechts der Isar, Technical University of Munich, Munich, Germany.
  • Sollmann N; Department of Diagnostic and Interventional Neuroradiology, School of Medicine, Klinikum rechts der Isar, Technical University of Munich, Munich, Germany.
Sci Rep ; 13(1): 5054, 2023 03 28.
Article em En | MEDLINE | ID: mdl-36977710
ABSTRACT
This study aimed to systematically evaluate the impact of dose reduction on image quality and confidence for intervention planning and guidance regarding computed tomography (CT)-based intervertebral disc and vertebral body biopsies. We retrospectively analyzed 96 patients who underwent multi-detector CT (MDCT) acquired for the purpose of biopsies, which were either derived from scanning with standard dose (SD) or low dose (LD; using tube current reduction). The SD cases were matched to LD cases considering sex, age, level of biopsy, presence of spinal instrumentation, and body diameter. All images for planning (reconstruction "IMR1") and periprocedural guidance (reconstruction "iDose4") were evaluated by two readers (R1 and R2) using Likert scales. Image noise was measured using attenuation values of paraspinal muscle tissue. The dose length product (DLP) was statistically significantly lower for LD scans regarding the planning scans (SD 13.8 ± 8.2 mGy*cm, LD 8.1 ± 4.4 mGy*cm, p < 0.01) and the interventional guidance scans (SD 43.0 ± 48.8 mGy*cm, LD 18.4 ± 7.3 mGy*cm, p < 0.01). Image quality, contrast, determination of the target structure, and confidence for planning or intervention guidance were rated good to perfect for SD and LD scans, showing no statistically significant differences between SD and LD scans (p > 0.05). Image noise was similar between SD and LD scans performed for planning of the interventional procedures (SD 14.62 ± 2.83 HU vs. LD 15.45 ± 3.22 HU, p = 0.24). Use of a LD protocol for MDCT-guided biopsies along the spine is a practical alternative, maintaining overall image quality and confidence. Increasing availability of model-based iterative reconstruction in clinical routine may facilitate further radiation dose reductions.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Tomografia Computadorizada Multidetectores / Redução da Medicação Tipo de estudo: Guideline / Observational_studies Limite: Humans Idioma: En Ano de publicação: 2023 Tipo de documento: Article