Your browser doesn't support javascript.
loading
Development of Novel Microwell-Based Spectrofluorimetry and High-Performance Liquid Chromatography with Fluorescence Detection Methods and High Throughput for Quantitation of Alectinib in Bulk Powder and Urine Samples.
Almutairi, Halah S; Alanazi, Mohammed M; Darwish, Ibrahim A; Bakheit, Ahmed H; Alshehri, Mona M; Darwish, Hany W.
Afiliação
  • Almutairi HS; Department of Pharmaceutical Chemistry, College of Pharmacy, King Saud University, P.O. Box 2457, Riyadh 11451, Saudi Arabia.
  • Alanazi MM; Department of Pharmaceutical Chemistry, College of Pharmacy, King Saud University, P.O. Box 2457, Riyadh 11451, Saudi Arabia.
  • Darwish IA; Department of Pharmaceutical Chemistry, College of Pharmacy, King Saud University, P.O. Box 2457, Riyadh 11451, Saudi Arabia.
  • Bakheit AH; Department of Pharmaceutical Chemistry, College of Pharmacy, King Saud University, P.O. Box 2457, Riyadh 11451, Saudi Arabia.
  • Alshehri MM; Department of Pharmaceutical Chemistry, College of Pharmacy, King Saud University, P.O. Box 2457, Riyadh 11451, Saudi Arabia.
  • Darwish HW; Department of Pharmaceutical Chemistry, College of Pharmacy, King Saud University, P.O. Box 2457, Riyadh 11451, Saudi Arabia.
Medicina (Kaunas) ; 59(3)2023 Feb 23.
Article em En | MEDLINE | ID: mdl-36984441
ABSTRACT
Background and

Objectives:

This study presents the development and validation of the 96-microwell-based spectrofluorimetric (MW-SFL) and high performance liquid chromatography (HPLC) with fluorescence detection (HPLC-FD) methods for the quantitation of alectinib (ALC) in its bulk powder form and in urine samples. Materials and

Methods:

The MW-SFL was based on the enhancement of the native fluorescence of ALC by the formation of micelles with the surfactant cremophor RH 40 (Cr RH 40) in aqueous media. The MW-SFL was executed in a 96-microwell plate and the relative fluorescence intensity (RFI) was recorded by utilizing a fluorescence plate reader at 450 nm after excitation at 280 nm. The HPLC-FD involved the chromatographic separation of ALC and ponatinib (PTB), as an internal standard (IS), on a C18 column and a mobile phase composed of methanolpotassium dihydrogen phosphate pH 7 (8020, v/v) at a flow rate of 2 mL min-1. The eluted ALC and PTB were detected by utilizing a fluorescence detector set at 365 nm for excitation and 450 nm for emission.

Results:

Validation of the MW-SFL and HPLC-FD analytical methods was carried out in accordance with the recommendations issued by the International Council for Harmonization (ICH) for the process of validating analytical procedures. Both methods were efficaciously applied for ALC quantitation in its bulk form as well as in spiked urine; the mean recovery values were ≥86.90 and 95.45% for the MW-SFL and HPLC-FD methods, respectively.

Conclusions:

Both methodologies are valuable for routine use in quality control (QC) laboratories for determination of ALC in pure powder form and in human urine samples.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Piperidinas / Carbazóis Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Piperidinas / Carbazóis Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Ano de publicação: 2023 Tipo de documento: Article