Your browser doesn't support javascript.
loading
False-positive magnetic resonance imaging prostate cancer correlates and clinical implications.
Arafa, Mostafa A; Rabah, Danny M; Khan, Farrukh; Farhat, Karim Hamda; Ibrahim, Nahla Khamis; Albekairi, Alanoud A.
Afiliação
  • Arafa MA; The Cancer Research Chair, King Saud University, Riyadh, Saudi Arabia.
  • Rabah DM; Department of Epidemiology, High Institute of Public Health, Alexandria University, Alexandria, Egypt.
  • Khan F; The Cancer Research Chair, King Saud University, Riyadh, Saudi Arabia.
  • Farhat KH; Departemnet of Surgery, College of Medicine, King Saud University, Riyadh, Saudi Arabia.
  • Ibrahim NK; Departemnet of Surgery, College of Medicine, King Saud University, Riyadh, Saudi Arabia.
  • Albekairi AA; The Cancer Research Chair, King Saud University, Riyadh, Saudi Arabia.
Urol Ann ; 15(1): 54-59, 2023.
Article em En | MEDLINE | ID: mdl-37006206
ABSTRACT

Background:

False-positive (FP) multiparametric magnetic resonance imaging (MPMRI) obscures and swift needless biopsies in men with a high prostate-specific antigen. Materials and

Methods:

This was a retrospective study, in which all patients who had been exposed to consecutive MP-MRI of the prostate combined with transrectal ultrasound-guided-magnetic resonance imaging fusion-guided prostate biopsy between 2017 and 2020 were involved in the study. The FP was measured as the number of biopsies that did not encompass prostate cancer divided by the whole number of biopsies.

Results:

The percentage of FP cases was 51.1%, the highest percentage was found in Prostate Imaging-Reporting and Data System (PI-RADs) 3 (37.7%) and the lowest was detected in PI-RAD 5 (14.5%). Those with FP biopsies are younger, and their total prostate antigen (PSA) and PSA density (PSAD) are significantly lesser. The area under the curve PSAD, age, and total PSA are 0.76, 0.74, and 0.69, respectively. An optimum PSAD value of 0.135 was chosen as a cutoff because it showed the highest sum of sensitivity and specificity, 68% and 69%, respectively.

Conclusion:

FP results of mpMRI were detected in more than half of our sample, more than one-third were presented in Pi-RAD3, improved imaging techniques to decrease FP rates are highly needed.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Tipo de estudo: Observational_studies / Prognostic_studies Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Tipo de estudo: Observational_studies / Prognostic_studies Idioma: En Ano de publicação: 2023 Tipo de documento: Article