Seeing More with Less: Clinical Benefits of Photon-counting Detector CT.
Nehra, Avinash K; Rajendran, Kishore; Baffour, Francis I; Mileto, Achille; Rajiah, Prabhakar Shantha; Horst, Kelly K; Inoue, Akitoshi; Johnson, Tucker F; Diehn, Felix E; Glazebrook, Katrina N; Thorne, Jamison E; Weber, Nikkole M; Shanblatt, Elisabeth R; Gong, Hao; Yu, Lifeng; Leng, Shuai; McCollough, Cynthia H; Fletcher, Joel G.
Afiliação
  • Nehra AK; From the Department of Radiology, Mayo Clinic, 200 1st St SW, Rochester, MN 55905 (A.K.N., K.R., F.I.B., P.S.R., K.K.H., T.F.G., F.E.D., K.N.G., J.E.T., N.M.W., H.G., L.Y., S.L., C.H.M., J.G.F.); Siemens Medical Solutions USA, Malvern, Pa (E.R.S.); Department of Radiology, Virginia Mason Medical Cen
  • Rajendran K; From the Department of Radiology, Mayo Clinic, 200 1st St SW, Rochester, MN 55905 (A.K.N., K.R., F.I.B., P.S.R., K.K.H., T.F.G., F.E.D., K.N.G., J.E.T., N.M.W., H.G., L.Y., S.L., C.H.M., J.G.F.); Siemens Medical Solutions USA, Malvern, Pa (E.R.S.); Department of Radiology, Virginia Mason Medical Cen
  • Baffour FI; From the Department of Radiology, Mayo Clinic, 200 1st St SW, Rochester, MN 55905 (A.K.N., K.R., F.I.B., P.S.R., K.K.H., T.F.G., F.E.D., K.N.G., J.E.T., N.M.W., H.G., L.Y., S.L., C.H.M., J.G.F.); Siemens Medical Solutions USA, Malvern, Pa (E.R.S.); Department of Radiology, Virginia Mason Medical Cen
  • Mileto A; From the Department of Radiology, Mayo Clinic, 200 1st St SW, Rochester, MN 55905 (A.K.N., K.R., F.I.B., P.S.R., K.K.H., T.F.G., F.E.D., K.N.G., J.E.T., N.M.W., H.G., L.Y., S.L., C.H.M., J.G.F.); Siemens Medical Solutions USA, Malvern, Pa (E.R.S.); Department of Radiology, Virginia Mason Medical Cen
  • Rajiah PS; From the Department of Radiology, Mayo Clinic, 200 1st St SW, Rochester, MN 55905 (A.K.N., K.R., F.I.B., P.S.R., K.K.H., T.F.G., F.E.D., K.N.G., J.E.T., N.M.W., H.G., L.Y., S.L., C.H.M., J.G.F.); Siemens Medical Solutions USA, Malvern, Pa (E.R.S.); Department of Radiology, Virginia Mason Medical Cen
  • Horst KK; From the Department of Radiology, Mayo Clinic, 200 1st St SW, Rochester, MN 55905 (A.K.N., K.R., F.I.B., P.S.R., K.K.H., T.F.G., F.E.D., K.N.G., J.E.T., N.M.W., H.G., L.Y., S.L., C.H.M., J.G.F.); Siemens Medical Solutions USA, Malvern, Pa (E.R.S.); Department of Radiology, Virginia Mason Medical Cen
  • Inoue A; From the Department of Radiology, Mayo Clinic, 200 1st St SW, Rochester, MN 55905 (A.K.N., K.R., F.I.B., P.S.R., K.K.H., T.F.G., F.E.D., K.N.G., J.E.T., N.M.W., H.G., L.Y., S.L., C.H.M., J.G.F.); Siemens Medical Solutions USA, Malvern, Pa (E.R.S.); Department of Radiology, Virginia Mason Medical Cen
  • Johnson TF; From the Department of Radiology, Mayo Clinic, 200 1st St SW, Rochester, MN 55905 (A.K.N., K.R., F.I.B., P.S.R., K.K.H., T.F.G., F.E.D., K.N.G., J.E.T., N.M.W., H.G., L.Y., S.L., C.H.M., J.G.F.); Siemens Medical Solutions USA, Malvern, Pa (E.R.S.); Department of Radiology, Virginia Mason Medical Cen
  • Diehn FE; From the Department of Radiology, Mayo Clinic, 200 1st St SW, Rochester, MN 55905 (A.K.N., K.R., F.I.B., P.S.R., K.K.H., T.F.G., F.E.D., K.N.G., J.E.T., N.M.W., H.G., L.Y., S.L., C.H.M., J.G.F.); Siemens Medical Solutions USA, Malvern, Pa (E.R.S.); Department of Radiology, Virginia Mason Medical Cen
  • Glazebrook KN; From the Department of Radiology, Mayo Clinic, 200 1st St SW, Rochester, MN 55905 (A.K.N., K.R., F.I.B., P.S.R., K.K.H., T.F.G., F.E.D., K.N.G., J.E.T., N.M.W., H.G., L.Y., S.L., C.H.M., J.G.F.); Siemens Medical Solutions USA, Malvern, Pa (E.R.S.); Department of Radiology, Virginia Mason Medical Cen
  • Thorne JE; From the Department of Radiology, Mayo Clinic, 200 1st St SW, Rochester, MN 55905 (A.K.N., K.R., F.I.B., P.S.R., K.K.H., T.F.G., F.E.D., K.N.G., J.E.T., N.M.W., H.G., L.Y., S.L., C.H.M., J.G.F.); Siemens Medical Solutions USA, Malvern, Pa (E.R.S.); Department of Radiology, Virginia Mason Medical Cen
  • Weber NM; From the Department of Radiology, Mayo Clinic, 200 1st St SW, Rochester, MN 55905 (A.K.N., K.R., F.I.B., P.S.R., K.K.H., T.F.G., F.E.D., K.N.G., J.E.T., N.M.W., H.G., L.Y., S.L., C.H.M., J.G.F.); Siemens Medical Solutions USA, Malvern, Pa (E.R.S.); Department of Radiology, Virginia Mason Medical Cen
  • Shanblatt ER; From the Department of Radiology, Mayo Clinic, 200 1st St SW, Rochester, MN 55905 (A.K.N., K.R., F.I.B., P.S.R., K.K.H., T.F.G., F.E.D., K.N.G., J.E.T., N.M.W., H.G., L.Y., S.L., C.H.M., J.G.F.); Siemens Medical Solutions USA, Malvern, Pa (E.R.S.); Department of Radiology, Virginia Mason Medical Cen
  • Gong H; From the Department of Radiology, Mayo Clinic, 200 1st St SW, Rochester, MN 55905 (A.K.N., K.R., F.I.B., P.S.R., K.K.H., T.F.G., F.E.D., K.N.G., J.E.T., N.M.W., H.G., L.Y., S.L., C.H.M., J.G.F.); Siemens Medical Solutions USA, Malvern, Pa (E.R.S.); Department of Radiology, Virginia Mason Medical Cen
  • Yu L; From the Department of Radiology, Mayo Clinic, 200 1st St SW, Rochester, MN 55905 (A.K.N., K.R., F.I.B., P.S.R., K.K.H., T.F.G., F.E.D., K.N.G., J.E.T., N.M.W., H.G., L.Y., S.L., C.H.M., J.G.F.); Siemens Medical Solutions USA, Malvern, Pa (E.R.S.); Department of Radiology, Virginia Mason Medical Cen
  • Leng S; From the Department of Radiology, Mayo Clinic, 200 1st St SW, Rochester, MN 55905 (A.K.N., K.R., F.I.B., P.S.R., K.K.H., T.F.G., F.E.D., K.N.G., J.E.T., N.M.W., H.G., L.Y., S.L., C.H.M., J.G.F.); Siemens Medical Solutions USA, Malvern, Pa (E.R.S.); Department of Radiology, Virginia Mason Medical Cen
  • McCollough CH; From the Department of Radiology, Mayo Clinic, 200 1st St SW, Rochester, MN 55905 (A.K.N., K.R., F.I.B., P.S.R., K.K.H., T.F.G., F.E.D., K.N.G., J.E.T., N.M.W., H.G., L.Y., S.L., C.H.M., J.G.F.); Siemens Medical Solutions USA, Malvern, Pa (E.R.S.); Department of Radiology, Virginia Mason Medical Cen
  • Fletcher JG; From the Department of Radiology, Mayo Clinic, 200 1st St SW, Rochester, MN 55905 (A.K.N., K.R., F.I.B., P.S.R., K.K.H., T.F.G., F.E.D., K.N.G., J.E.T., N.M.W., H.G., L.Y., S.L., C.H.M., J.G.F.); Siemens Medical Solutions USA, Malvern, Pa (E.R.S.); Department of Radiology, Virginia Mason Medical Cen
Radiographics ; 43(5): e220158, 2023 05.
Article em En | MEDLINE | ID: mdl-37022956
Photon-counting detector (PCD) CT is an emerging technology that has led to continued innovation and progress in diagnostic imaging after it was approved by the U.S. Food and Drug Administration for clinical use in September 2021. Conventional energy-integrating detector (EID) CT measures the total energy of x-rays by converting photons to visible light and subsequently using photodiodes to convert visible light to digital signals. In comparison, PCD CT directly records x-ray photons as electric signals, without intermediate conversion to visible light. The benefits of PCD CT systems include improved spatial resolution due to smaller detector pixels, higher iodine image contrast, increased geometric dose efficiency to allow high-resolution imaging, reduced radiation dose for all body parts, multienergy imaging capabilities, and reduced artifacts. To recognize these benefits, diagnostic applications of PCD CT in musculoskeletal, thoracic, neuroradiologic, cardiovascular, and abdominal imaging must be optimized and adapted for specific diagnostic tasks. The diagnostic benefits and clinical applications resulting from PCD CT in early studies have allowed improved visualization of key anatomic structures and radiologist confidence for some diagnostic tasks, which will continue as PCD CT evolves and clinical use and applications grow. ©RSNA, 2023 Quiz questions for this article are available in the supplemental material. See the invited commentary by Ananthakrishnan in this issue.