The increase in cardiac output induced by a decrease in positive end-expiratory pressure reliably detects volume responsiveness: the PEEP-test study.
Crit Care
; 27(1): 136, 2023 04 09.
Article
em En
| MEDLINE
| ID: mdl-37031182
ABSTRACT
BACKGROUND:
In patients on mechanical ventilation, positive end-expiratory pressure (PEEP) can decrease cardiac output through a decrease in cardiac preload and/or an increase in right ventricular afterload. Increase in central blood volume by fluid administration or passive leg raising (PLR) may reverse these phenomena through an increase in cardiac preload and/or a reopening of closed lung microvessels. We hypothesized that a transient decrease in PEEP (PEEP-test) may be used as a test to detect volume responsiveness.METHODS:
Mechanically ventilated patients with PEEP ≥ 10 cmH2O ("high level") and without spontaneous breathing were prospectively included. Volume responsiveness was assessed by a positive PLR-test, defined as an increase in pulse-contour-derived cardiac index (CI) during PLR ≥ 10%. The PEEP-test consisted in reducing PEEP from the high level to 5 cmH2O for one minute. Pulse-contour-derived CI (PiCCO2) was monitored during PLR and the PEEP-test.RESULTS:
We enrolled 64 patients among whom 31 were volume responsive. The median increase in CI during PLR was 14% (11-16%). The median PEEP at baseline was 12 (10-15) cmH2O and the PEEP-test resulted in a median decrease in PEEP of 7 (5-10) cmH2O, without difference between volume responsive and unresponsive patients. Among volume responsive patients, the PEEP-test induced a significant increase in CI of 16% (12-20%) (from 2.4 ± 0.7 to 2.9 ± 0.9 L/min/m2, p < 0.0001) in comparison with volume unresponsive patients. In volume unresponsive patients, PLR and the PEEP-test increased CI by 2% (1-5%) and 6% (3-8%), respectively. Volume responsiveness was predicted by an increase in CI > 8.6% during the PEEP-test with a sensitivity of 96.8% (95% confidence interval (95%CI) 83.3-99.9%) and a specificity of 84.9% (95%CI 68.1-94.9%). The area under the receiver operating characteristic curve of the PEEP-test for detecting volume responsiveness was 0.94 (95%CI 0.85-0.98) (p < 0.0001 vs. 0.5). Spearman's correlation coefficient between the changes in CI induced by PLR and the PEEP-test was 0.76 (95%CI 0.63-0.85, p < 0.0001).CONCLUSIONS:
A CI increase > 8.6% during a PEEP-test, which consists in reducing PEEP to 5 cmH2O, reliably detects volume responsiveness in mechanically ventilated patients with a PEEP ≥ 10 cmH2O. Trial registration ClinicalTrial.gov (NCT 04,023,786). Registered July 18, 2019. Ethics Committee approval CPP Est III (N° 2018-A01599-46).Palavras-chave
Texto completo:
1
Base de dados:
MEDLINE
Assunto principal:
Respiração Artificial
/
Volume Sanguíneo
/
Débito Cardíaco
/
Respiração com Pressão Positiva
/
Hidratação
/
Coração
Tipo de estudo:
Prognostic_studies
Limite:
Humans
Idioma:
En
Ano de publicação:
2023
Tipo de documento:
Article