Your browser doesn't support javascript.
loading
Correlation of head screw lengths in proximal humerus nailing: a CT-based study on 289 cases.
Sarter, Michael; Koslowsky, Thomas C; Fervers, Philipp; Bratke, Grischa; Harbrecht, Andreas; Hackl, Michael; Müller, Lars P; Wegmann, Kilian.
Afiliação
  • Sarter M; Center for Orthopedic and Trauma Surgery, University Medical Center of Cologne, Kerpenerstr. 62, 50937, Cologne, Germany. Michael.sarter@uk-koeln.de.
  • Koslowsky TC; Chirurgische Klinik, St. Elisabeth Hospital, Werthmannstraße 1, 50935, Cologne, Germany.
  • Fervers P; Department of Diagnostic and Interventional Radiology, University Medical Center of Cologne, Kerpenerstr. 62, 50937, Cologne, Germany.
  • Bratke G; Department of Diagnostic and Interventional Radiology, University Medical Center of Cologne, Kerpenerstr. 62, 50937, Cologne, Germany.
  • Harbrecht A; Center for Orthopedic and Trauma Surgery, University Medical Center of Cologne, Kerpenerstr. 62, 50937, Cologne, Germany.
  • Hackl M; Center for Orthopedic and Trauma Surgery, University Medical Center of Cologne, Kerpenerstr. 62, 50937, Cologne, Germany.
  • Müller LP; Center for Orthopedic and Trauma Surgery, University Medical Center of Cologne, Kerpenerstr. 62, 50937, Cologne, Germany.
  • Wegmann K; Center for Orthopedic and Trauma Surgery, University Medical Center of Cologne, Kerpenerstr. 62, 50937, Cologne, Germany.
Arch Orthop Trauma Surg ; 143(8): 5027-5034, 2023 Aug.
Article em En | MEDLINE | ID: mdl-37042984
INTRODUCTION: Nailing of the proximal humerus is an established method for the treatment of proximal humerus fractures. Choice of the correct length for potentially four proximal locking screws is essential for postoperative outcome. Due to positioning of the patient, intraoperative determination of the correct length of the anteroposterior (AP) screw with the x-ray beam is particularly challenging even for experienced surgeons. We hypothesized that there would be a correlation between the projected lengths of the different proximal locking screws and therefore the length of the AP-screw could be determined based on the three lateromedial (LM) screws. MATERIALS AND METHODS: In this retrospective study (level of evidence: III) CT-scans of shoulders of 289 patients were 3D reconstructed with the program Horos. Using the manufacturer Stryker's instructions, the four proximal locking screws of the T2 Humeral Nail system were reproduced in the 3D reconstructed shoulders. The length of the AP-screw was correlated with the lengths of the LM-screws by Linear Regression and Multiple Linear Regression. RESULTS: The results of this study showed that the lengths of proximal locking screws in proximal humeral nailing correlated significantly with each other. Based on the given data, a formula could be established to calculate the length of the AP-screw based on the lengths of the LM-screws with a probability of 76.5%. CONCLUSIONS: This study was able to show that the length of the AP-screw could be determined from the intraoperatively measured lengths of the LM-screws. As our findings base on measurements performed in CT scans, clinical studies are needed to support our data.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Fraturas do Ombro / Úmero Tipo de estudo: Observational_studies Limite: Humans Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Fraturas do Ombro / Úmero Tipo de estudo: Observational_studies Limite: Humans Idioma: En Ano de publicação: 2023 Tipo de documento: Article