Your browser doesn't support javascript.
loading
Photon-counting CT: Review of initial clinical results.
van der Bie, Judith; van Straten, Marcel; Booij, Ronald; Bos, Daniel; Dijkshoorn, Marcel L; Hirsch, Alexander; Sharma, Simran P; Oei, Edwin H G; Budde, Ricardo P J.
Afiliação
  • van der Bie J; Department of Radiology & Nuclear Medicine, Erasmus MC, University Medical Center Rotterdam, Rotterdam, the Netherlands. Electronic address: j.vanderbie@erasmusmc.nl.
  • van Straten M; Department of Radiology & Nuclear Medicine, Erasmus MC, University Medical Center Rotterdam, Rotterdam, the Netherlands. Electronic address: marcel.vanstraten@erasmusmc.nl.
  • Booij R; Department of Radiology & Nuclear Medicine, Erasmus MC, University Medical Center Rotterdam, Rotterdam, the Netherlands. Electronic address: r.booij@erasmusmc.nl.
  • Bos D; Department of Radiology & Nuclear Medicine, Erasmus MC, University Medical Center Rotterdam, Rotterdam, the Netherlands; Department of Epidemiology, Erasmus MC, University Medical Center Rotterdam, Rotterdam, the Netherlands. Electronic address: d.bos@erasmusmc.nl.
  • Dijkshoorn ML; Department of Radiology & Nuclear Medicine, Erasmus MC, University Medical Center Rotterdam, Rotterdam, the Netherlands. Electronic address: m.l.dijkshoorn@erasmusmc.nl.
  • Hirsch A; Department of Radiology & Nuclear Medicine, Erasmus MC, University Medical Center Rotterdam, Rotterdam, the Netherlands; Department of Cardiology, Erasmus MC, University Medical Center Rotterdam, Rotterdam, the Netherlands. Electronic address: a.hirsch@erasmusmc.nl.
  • Sharma SP; Department of Radiology & Nuclear Medicine, Erasmus MC, University Medical Center Rotterdam, Rotterdam, the Netherlands; Department of Cardiology, Erasmus MC, University Medical Center Rotterdam, Rotterdam, the Netherlands. Electronic address: s.sharma@erasmusmc.nl.
  • Oei EHG; Department of Radiology & Nuclear Medicine, Erasmus MC, University Medical Center Rotterdam, Rotterdam, the Netherlands. Electronic address: e.oei@erasmusmc.nl.
  • Budde RPJ; Department of Radiology & Nuclear Medicine, Erasmus MC, University Medical Center Rotterdam, Rotterdam, the Netherlands. Electronic address: r.budde@erasmusmc.nl.
Eur J Radiol ; 163: 110829, 2023 Jun.
Article em En | MEDLINE | ID: mdl-37080060
ABSTRACT
Photon-counting computed tomography (PCCT) is a new technology that enables higher spatial resolution compared to conventional CT techniques, energy resolved imaging and spectral post-processing. This leads to improved contrast-to-noise ratio, artifact and potential dose reduction as well as elimination of electronic noise. Since the introduction of clinical PCCT in 2021, a shift has been observed from solely pre-clinical studies to clinical research (i.e. use of PCCT imaging in humans). This review article is focused on the initial clinical results of PCCT by explaining the current PCCT systems, the applications themselves and, the challenges of PCCT.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Tomografia Computadorizada por Raios X Limite: Humans Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Tomografia Computadorizada por Raios X Limite: Humans Idioma: En Ano de publicação: 2023 Tipo de documento: Article