Your browser doesn't support javascript.
loading
Flowsheet modelling of a powder continuous feeder-mixer system.
Dias, Rute C; Korhonen, Ossi; Ketolainen, Jarkko; Lopes, João A; Ervasti, Tuomas.
Afiliação
  • Dias RC; PromisLab, School of Pharmacy, University of Eastern Finland, 70211 Kuopio, Finland; iMed.ULisboa, Faculty of Pharmacy, University of Lisbon, 1649-003 Lisbon, Portugal. Electronic address: rdias@campus.ul.pt.
  • Korhonen O; PromisLab, School of Pharmacy, University of Eastern Finland, 70211 Kuopio, Finland.
  • Ketolainen J; PromisLab, School of Pharmacy, University of Eastern Finland, 70211 Kuopio, Finland.
  • Lopes JA; iMed.ULisboa, Faculty of Pharmacy, University of Lisbon, 1649-003 Lisbon, Portugal.
  • Ervasti T; PromisLab, School of Pharmacy, University of Eastern Finland, 70211 Kuopio, Finland.
Int J Pharm ; 639: 122969, 2023 May 25.
Article em En | MEDLINE | ID: mdl-37084833
ABSTRACT
In this study, an integrated flowsheet model of the continuous feeder-mixer system was calibrated, simulated and compared against experimental data. The feeding process was first investigated using two major components (ibuprofen and microcrystalline cellulose (MCC)), in a formulation comprised of 30 wt% of ibuprofen, 67.5 wt% MCC, 2 wt% of sodium starch glycolate and 0.5 wt% of magnesium stearate. The impact of a refill on feeder performance was experimentally evaluated for different operating conditions. Results showed that it had no influence on feeder performance. While simulations with the feeder model fairly reproduced the material behaviour observed in the feeder, unintended disturbances were underpredicted due to the model's low complexity. Experimentally, mixer's efficiency was assessed based on ibuprofen residence time distribution. Mean residence time pointed to a higher mixer's efficiency at lower flow rates. Blend homogeneity results showed that for the entire set of experiments, ibuprofen RSD < 5%, irrespective of process variables. A feeder-mixer flowsheet model was calibrated, after regressing the axial model coefficients. The regression curves exhibited a R2 above 0.96, whereas the RMSE varied from 1.58x10-4 to 1.06x10-3 s-1 across all fitted curves. Simulations confirmed that flowsheet model captured the powder dynamics inside the mixer and qualitatively predicted the mixer's filtering ability against feeding composition fluctuations, as well as ibuprofen RSD in blend, in line with real experiments.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Ibuprofeno / Tecnologia Farmacêutica Tipo de estudo: Prognostic_studies Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Ibuprofeno / Tecnologia Farmacêutica Tipo de estudo: Prognostic_studies Idioma: En Ano de publicação: 2023 Tipo de documento: Article