Your browser doesn't support javascript.
loading
Effect of the pulsed electromagnetic field in the repair of a calvaria critical bone defect in rats: cone beam computed tomographic and histomorphometric analysis.: PEMF in the repair of a calvaria critical bone defect: CBCT analyses.
Moura, Nicole Bertonde; Ferreira, Camila Lopes; Lima, Victória Clarada Silva; Nunes, Camilla Magnoni Moretto; de Marco, Andrea Carvalho; Costa, André Luiz Ferreira; Lopes, Sérgio Lúcio Pereirade Castro; Jardini, Maria Aparecida Neves.
Afiliação
  • Moura NB; Graduate student of institute of Science and Technology of Sao Jose dos Campos, Universidade Estadual Paulista (Unesp), São José dos Campos, SP, Brazil.
  • Ferreira CL; Department of Diagnosis and Surgery, Institute of Science and Technology of Sao Jose dos Campos, Universidade Estadual Paulista (unesp), Sao Jose dos Campos, SP, Brazil.
  • Lima VCS; Graduate student of institute of Science and Technology of Sao Jose dos Campos, Universidade Estadual Paulista (Unesp), São José dos Campos, SP, Brazil.
  • Nunes CMM; Department of Diagnosis and Surgery, Institute of Science and Technology of Sao Jose dos Campos, Universidade Estadual Paulista (unesp), Sao Jose dos Campos, SP, Brazil.
  • de Marco AC; Department of Diagnosis and Surgery, Institute of Science and Technology of Sao Jose dos Campos, Universidade Estadual Paulista (unesp), Sao Jose dos Campos, SP, Brazil.
  • Costa ALF; Postgraduate Program in Dentistry, Cruzeiro do Sul University (UNICSUL), Sao Paulo, Sao Paulo, Brazil.
  • Lopes SLPC; Department of Diagnosis and Surgery, Institute of Science and Technology of Sao Jose dos Campos, Universidade Estadual Paulista (unesp), Sao Jose dos Campos, SP, Brazil.
  • Jardini MAN; Department of Diagnosis and Surgery, Institute of Science and Technology of Sao Jose dos Campos, Universidade Estadual Paulista (unesp), Sao Jose dos Campos, SP, Brazil. Electronic address: maria.jardini@unesp.br.
J Stomatol Oral Maxillofac Surg ; 124(6S): 101483, 2023 Dec.
Article em En | MEDLINE | ID: mdl-37100171

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Campos Eletromagnéticos / Tomografia Computadorizada de Feixe Cônico Espiral Tipo de estudo: Guideline Limite: Animals / Humans Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Campos Eletromagnéticos / Tomografia Computadorizada de Feixe Cônico Espiral Tipo de estudo: Guideline Limite: Animals / Humans Idioma: En Ano de publicação: 2023 Tipo de documento: Article