Your browser doesn't support javascript.
loading
RT-nestRPA is a new technology for the rapid and sensitive detection of nucleic acid detection of pathogens used for a variety of medical application scenarios.
Huang, Wanqiu; Zhang, Zhaoqi; Lin, Dachuan; Deng, Yuliang; Chen, Xinchun; Huang, Jian.
Afiliação
  • Huang W; Key Laboratory of Systems Biomedicine (Ministry of Education), Shanghai Centre for Systems Biomedicine, Shanghai Jiao Tong University, Shanghai, 200240, China. Electronic address: wqhuang@sjtu.edu.cn.
  • Zhang Z; Department of General Surgery, Shanghai General Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200080, China.
  • Lin D; Guangdong Key Laboratory of Regional Immunity and Diseases, Department of Pathology Biology, School of Medicine, Shenzhen University, Shenzhen, 518060, China.
  • Deng Y; Key Laboratory of Systems Biomedicine (Ministry of Education), Shanghai Centre for Systems Biomedicine, Shanghai Jiao Tong University, Shanghai, 200240, China.
  • Chen X; Guangdong Key Laboratory of Regional Immunity and Diseases, Department of Pathology Biology, School of Medicine, Shenzhen University, Shenzhen, 518060, China.
  • Huang J; Key Laboratory of Systems Biomedicine (Ministry of Education), Shanghai Centre for Systems Biomedicine, Shanghai Jiao Tong University, Shanghai, 200240, China. Electronic address: jianhuang@sjtu.edu.cn.
Anal Chim Acta ; 1262: 341263, 2023 Jun 29.
Article em En | MEDLINE | ID: mdl-37179064
ABSTRACT

BACKGROUND:

The effective detection of pathogens is of great importance for the diagnosis and treatment of infectious diseases. We have proposed the novel RT-nestRPA technique for SARS-CoV-2 detection, which is a rapid RNA detection technique with ultra-high sensitivity.

RESULTS:

The RT-nestRPA technology has a sensitivity of 0.5 copies/uL of synthetic RNA targeting the ORF7a/7b/8 gene or 1 copy/uL synthetic RNA targeting the N gene of SARS-CoV-2. The entire detection process of RT-nestRPA only takes only 20 min, which is significantly shorter than RT-qPCR (nearly 100 min). Additionally, RT-nestRPA is capable of detecting dual genes of SARS-CoV-2 and human RPP30 simultaneously in one reaction tube. The excellent specificity of RT-nestRPA was verified by analyzing twenty-two SARS-CoV-2 unrelated pathogens. Furthermore, RT-nestRPA had great performance in detecting samples treated with cell lysis buffer without RNA extraction. The innovative double-layer reaction tube for RT-nestRPA can prevent aerosol contamination and simplify the reaction operation. Moreover, the ROC analysis revealed that RT-nestRPA had high diagnostic value (AUC = 0.98), while the AUC of RT-qPCR was 0.75.

SIGNIFICANCE:

Our current findings suggested that RT-nestRPA could serve as a novel technology for nucleic acid detection of pathogens with rapid and ultrahigh sensitive features used in various medical application scenarios.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: SARS-CoV-2 / COVID-19 Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: SARS-CoV-2 / COVID-19 Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Ano de publicação: 2023 Tipo de documento: Article