Engineering of An Aptamer-Functionalized Fluorescent DNA Sensor for Cu(II) Responding in Living Tumor Cells.
Mou, Yue; Yin, Peng; Chen, Meiyun; Wei, Chonghui; Zhang, Yanfei; Zhang, Jiaheng; Zhao, Yujie; Luo, Xingyu; Wang, Yilin.
Afiliação
  • Mou Y; School of Chemistry and Chemical Engineering, Guangxi University, Nanning, Guangxi 530004, P.R. China.
  • Yin P; State Key Laboratory of Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University, Changsha, Hunan 410082, P. R. China.
  • Chen M; School of Chemistry and Chemical Engineering, Guangxi University, Nanning, Guangxi 530004, P.R. China.
  • Wei C; School of Chemistry and Chemical Engineering, Guangxi University, Nanning, Guangxi 530004, P.R. China.
  • Zhang Y; School of Chemistry and Chemical Engineering, Guangxi University, Nanning, Guangxi 530004, P.R. China.
  • Zhang J; College of Chemistry, Zhengzhou University, Zhengzhou, Henan 450001, P.R. China.
  • Zhao Y; State Key Laboratory of Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University, Changsha, Hunan 410082, P. R. China.
  • Luo X; School of Chemistry and Chemical Engineering, Guangxi University, Nanning, Guangxi 530004, P.R. China.
  • Wang Y; School of Chemistry and Chemical Engineering, Guangxi University, Nanning, Guangxi 530004, P.R. China.
Anal Chem ; 95(21): 8348-8356, 2023 05 30.
Article em En | MEDLINE | ID: mdl-37194189
ABSTRACT
Copper ions play vital roles in regulating life processes and being closely involved in several diseases such as cancer. Although detection methods based on fluorescent sensors or other strategies have been developed, it still remains a challenge to simultaneously realize the convenience, specificity, and accuracy in intracellular copper ion analysis. Herein, we propose an aptamer-functionalized DNA fluorescent sensor (AFDS) for accurate and specific detection of Cu(II) both in vitro and in cells by engineering the linkage of two DNA aptamers, namely, Lettuce aptamer and AS1411 aptamer, to achieve the manner of recognition response. Taking advantage of the functions of each aptamer, the tumor cell recognition capability and the high-contrast detection performance are simultaneously equipped in the AFDS. Furthermore, the AFDS shows high specificity and selectivity in Cu(II) response to avoid interference from common metal ions, chelators, and reactants by being associated with the irreversible interaction between nucleobases and Cu(II), which can destroy the topological structures and switch off the fluorescence of the AFDS. It also enables a sensitive in vitro detection of Cu(II) with a detection limit as lower as 0.1 µM and a wide detection linear range from 0.1 to 300 µM. The feasibility and superiority of the AFDS provide an opportunity to reveal both concentration-dependent and time-dependent intracellular Cu(II) responses in living cells. Therefore, the AFDS has achieved the novel detection performance of Cu(II) to exhibit great potential in exploring copper-related biological and pathological research.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Cobre / Metais Idioma: En Ano de publicação: 2023 Tipo de documento: Article