Your browser doesn't support javascript.
loading
Side-by-side deployment of gore excluder legs at a narrow terminal aorta for endovascular aneurysm repair.
Hohri, Yu; Kawajiri, Hidetake; Kanda, Keiichi; Numata, Satoshi; Kobayashi, Takuma; Nakai, Rie; Yaku, Hitoshi.
Afiliação
  • Hohri Y; Department of Cardiovascular Surgery, Kyoto Prefectural University of Medicine, 465 Kajii-Cho, Kawaramachi Hirokoji, Kamigyo-Ku, Kyoto, 602-8566, Japan. hohri.kpum5@gmail.com.
  • Kawajiri H; Department of Cardiovascular Surgery, Kyoto Prefectural University of Medicine, 465 Kajii-Cho, Kawaramachi Hirokoji, Kamigyo-Ku, Kyoto, 602-8566, Japan. kawajiri@koto.kpu-m.ac.jp.
  • Kanda K; Department of Cardiovascular Surgery, Kyoto Prefectural University of Medicine, 465 Kajii-Cho, Kawaramachi Hirokoji, Kamigyo-Ku, Kyoto, 602-8566, Japan.
  • Numata S; Department of Cardiovascular Surgery, Kyoto Prefectural University of Medicine, 465 Kajii-Cho, Kawaramachi Hirokoji, Kamigyo-Ku, Kyoto, 602-8566, Japan.
  • Kobayashi T; Department of Cardiovascular Surgery, Kyoto Prefectural University of Medicine, 465 Kajii-Cho, Kawaramachi Hirokoji, Kamigyo-Ku, Kyoto, 602-8566, Japan.
  • Nakai R; Department of Cardiovascular Surgery, Kyoto Prefectural University of Medicine, 465 Kajii-Cho, Kawaramachi Hirokoji, Kamigyo-Ku, Kyoto, 602-8566, Japan.
  • Yaku H; Department of Cardiovascular Surgery, Kyoto Prefectural University of Medicine, 465 Kajii-Cho, Kawaramachi Hirokoji, Kamigyo-Ku, Kyoto, 602-8566, Japan.
J Artif Organs ; 2023 May 25.
Article em En | MEDLINE | ID: mdl-37227546
PURPOSE: A narrow terminal aorta is a risk factor for endograft occlusion after endovascular aneurysm repair. To minimize limb complications, we used Gore Excluder legs positioned side-by-side at the terminal aorta. We investigated the outcomes of our strategy for endovascular aneurysm repair in patients with a narrow terminal aorta. METHODS: We enrolled 61 patients who underwent endovascular aneurysm repair with a narrow terminal aorta (defined as < 18 mm in diameter) from April 2013 to October 2021. The standard procedure involves complete treatment with the Gore Excluder device. When other types of main body endografts were used, they were deployed proximal to the terminal aorta, and we used the Gore Excluder leg device in the bilateral limbs. Postoperatively, the intraluminal diameter of the legs at the terminal aorta was measured to assess the configuration. RESULTS: During the follow-up period (mean: 2.7 ± 2.0 years), there were no aorta-related deaths, endograft occlusions, or leg-related re-interventions. There were no significant differences between the pre- and postoperative ankle-brachial pressure index values in the dominant and non-dominant legs (p = 0.44 and p = 0.17, respectively). Postoperatively, the mean difference rate (defined as [dominant leg diameter-non-dominant leg diameter]/terminal aorta diameter) was 7.5 ± 7.1%. The difference rate was not significantly correlated with the terminal aortic diameter, calcification thickness, or circumferential calcification (r = 0.16, p = 0.22; r = 0.07, p = 0.59; and r = - 0.07, p = 0.61, respectively). CONCLUSIONS: Side-by-side deployment of Gore Excluder legs produces acceptable outcomes for endovascular aneurysm repair with a narrow terminal aorta. The endograft expansion at the terminal aorta is tolerable without influencing calcification distribution.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Tipo de estudo: Risk_factors_studies Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Tipo de estudo: Risk_factors_studies Idioma: En Ano de publicação: 2023 Tipo de documento: Article