Your browser doesn't support javascript.
loading
Effects of Propofol on Perioperative Sleep Quality in Patients Undergoing Gastrointestinal Endoscopy: A Prospective Cohort Study.
Wu, Xiaofei; Deng, Jinhe; Li, Xiaona; Yang, Li; Zhao, Gaofeng; Yin, Qing; Shi, Yongyong; Tong, Zhilan.
Afiliação
  • Wu X; Department of Anesthesiology, The Second Affiliated Hospital of Guangzhou University of Traditional Chinese Medicine, Guangzhou, Guangdong, China.
  • Deng J; Department of Anesthesiology, The Second Affiliated Hospital of Guangzhou University of Traditional Chinese Medicine, Guangzhou, Guangdong, China.
  • Li X; Department of Anesthesiology, The Second Affiliated Hospital of Guangzhou University of Traditional Chinese Medicine, Guangzhou, Guangdong, China.
  • Yang L; Department of Anesthesiology, The Second Affiliated Hospital of Guangzhou University of Traditional Chinese Medicine, Guangzhou, Guangdong, China.
  • Zhao G; Department of Anesthesiology, The Second Affiliated Hospital of Guangzhou University of Traditional Chinese Medicine, Guangzhou, Guangdong, China.
  • Yin Q; Department of Anesthesiology, The Second Affiliated Hospital of Guangzhou University of Traditional Chinese Medicine, Guangzhou, Guangdong, China.
  • Shi Y; Department of Anesthesiology, The Second Affiliated Hospital of Guangzhou University of Traditional Chinese Medicine, Guangzhou, Guangdong, China.
  • Tong Z; Department of Anesthesiology, The Second Affiliated Hospital of Guangzhou University of Traditional Chinese Medicine, Guangzhou, Guangdong, China. Electronic address: 15918670863@139.com.
J Perianesth Nurs ; 38(5): 787-791, 2023 10.
Article em En | MEDLINE | ID: mdl-37269278
ABSTRACT

PURPOSE:

Some patients experience sleep disturbances after endoscopy performed under sedation. This study aimed to evaluate the effects of propofol on sleep quality after gastrointestinal endoscopy (GE).

DESIGN:

This study was a prospective cohort study.

METHODS:

This study enrolled 880 patients who underwent GE. Patients who chose to undergo GE under sedation received intravenous propofol, whereas the control group did not. The Pittsburgh Sleep Quality Index (PSQI) was measured before GE (PSQI-1) and 3 weeks (PSQI-2) after GE. The Groningen Sleep Score Scale (GSQS) was used before GE (GSQS-1) and 1 (GSQS-2) and 7 days (GSQS-3) after GE.

FINDINGS:

There was a significant increase in GSQS scores from baseline to days 1 and 7 after GE (GSQS-2 vs GSQS-1, P < .001, GSQS-3 vs GSQS-1, P = .008). However, no significant changes were observed in the control group (GSQS-2 vs GSQS-1, P = .38, GSQS-3 vs GSQS-1, P = .66). On day 21, there were no significant changes in the baseline PSQI scores over time in either group (sedation group, P = .96; control group, P = .95).

CONCLUSIONS:

GE with propofol sedation negatively affected sleep quality for 7 days after GE but not 3 weeks after GE.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Propofol Tipo de estudo: Etiology_studies / Observational_studies Limite: Humans Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Propofol Tipo de estudo: Etiology_studies / Observational_studies Limite: Humans Idioma: En Ano de publicação: 2023 Tipo de documento: Article