Static Respiratory System Compliance as a Predictor of Extubation Failure in Patients with Acute Respiratory Failure.
Abplanalp, Lauren A; Ionescu, Filip; Calvo-Ayala, Enrique; Yu, Limin; Nair, Girish B.
Afiliação
  • Abplanalp LA; Division of Pulmonary and Critical Care, Beaumont Health, Royal Oak, MI, USA.
  • Ionescu F; OUWB School of Medicine, Rochester, MI, USA.
  • Calvo-Ayala E; OUWB School of Medicine, Rochester, MI, USA.
  • Yu L; Moffitt Cancer Center, University of South Florida Morsani Medical School, Tampa, FL, USA.
  • Nair GB; Division of Pulmonary and Critical Care, Beaumont Health, Royal Oak, MI, USA.
Lung ; 201(3): 309-314, 2023 06.
Article em En | MEDLINE | ID: mdl-37300706
ABSTRACT

PURPOSE:

Ventilator weaning protocols rely in part on objective indices to best predict extubation failure in the critically ill. We investigated static respiratory system compliance (RC) as a predictor of extubation failure, in comparison to extubation readiness using rapid shallow breathing index (RSBI). MATERIAL AND

METHODS:

This was a cross-sectional, multi-institutional study of mechanically ventilated patients admitted between 12/01/2017 and 12/01/2019. All patients older than 18 years with a documented spontaneous breathing trial and extubation trial were included. RC and RSBI were calculated prior to the extubation trial. The primary outcome was extubation failure-defined as need for reintubation within 72 h from time of extubation.

RESULTS:

Of the 2263 patients, 55.8% were males with a mean age of 68 years. The population consisted mostly of Caucasians (73%) and African Americans (20.4%). 274 (12.1%) patients required reintubation within 72 h. On multivariate logistic regression after adjusting for age, sex, body mass index (BMI), admission Sequential Organ Failure Assessment (SOFA) score, number of ventilator days, and the P/F ratio on the day of extubation, RC remained the strongest predictor for extubation failure at 24 h (aOR 1.45; 95% CI 1.00-2.10) and 72 h (aOR 1.58; 95% CI 1.15-2.17). There was no significant association between RSBI and extubation failure at 24 (aOR 1.00; 95% CI 0.99-1.01) or at 72 h (aOR 1.00; 95% CI 0.99-1.01).

CONCLUSION:

RC measured on the day of extubation is a promising physiological discriminant to potentially risk stratify patients with acute respiratory failure for extubation readiness. We recommend further validation studies in prospective cohorts.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Insuficiência Respiratória / Extubação Tipo de estudo: Clinical_trials / Observational_studies / Prevalence_studies / Prognostic_studies / Risk_factors_studies Limite: Aged / Female / Humans / Male Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Insuficiência Respiratória / Extubação Tipo de estudo: Clinical_trials / Observational_studies / Prevalence_studies / Prognostic_studies / Risk_factors_studies Limite: Aged / Female / Humans / Male Idioma: En Ano de publicação: 2023 Tipo de documento: Article