Radioimmunoimaging of experimental thrombi in dogs using technetium-99m-labeled monoclonal antibody fragments reactive with human platelets.
J Nucl Med
; 27(8): 1315-20, 1986 Aug.
Article
em En
| MEDLINE
| ID: mdl-3734905
ABSTRACT
Monoclonal antibody 50H.19, which reacts with human platelets, was converted to fragments, pretinned, and made into kits for subsequent radiolabeling with 99mTc. The antibody, which cross-reacts with dog platelets, was used to evaluate in vitro binding to blood clots and in vivo in experimental thrombi in dogs. After radiolabeling, 97.4 +/- 6.4% of the 99mTc was antibody-associated. The preparations retained immunoreactivity, as determined by binding studies using whole blood and determining the ratio of cell-to-plasma radioactivity (ratios of 57.6-61.2) and binding of the antibody to clots (clot/serum ratios were 57.2-74.6%). Approximately 50% of the radioactivity was cleared from the blood in 3-6 min and 18-24% was excreted in urine within 3 hr. Experimental thrombi in dogs could be visualized consistently within 2-3 hr postinjection in peripheral veins and arteries, pulmonary arteries, and the right ventricle. In addition, damage to blood vessel intima without visible thrombi could also be detected. This method has the following advantages short and simple pre-imaging preparation, and rapid visualization of thrombi with no need for blood-pool subtraction or delayed imaging.
Buscar no Google
Base de dados:
MEDLINE
Assunto principal:
Trombose
/
Tecnécio
/
Anticorpos Monoclonais
Limite:
Animals
Idioma:
En
Ano de publicação:
1986
Tipo de documento:
Article