Your browser doesn't support javascript.
loading
Suture Augmentation of a Four-Strand Semitendinosus Graft Improves Time-Zero Biomechanical Properties.
Wallace, Garrett J; Thompson, J Daniel; Diekfuss, Jed A; Champagne, Allen A; Myer, Gregory D; Kaiser, Jarred; Lamplot, Joseph D.
Afiliação
  • Wallace GJ; Department of Orthopaedics, Emory University School of Medicine, Atlanta, Georgia, USA.
  • Thompson JD; Department of Orthopaedics, Emory University School of Medicine, Atlanta, Georgia, USA.
  • Diekfuss JA; Department of Orthopaedics, Emory University School of Medicine, Atlanta, Georgia, USA; Emory Sports Performance and Research Center (SPARC), Flowery Branch, Georgia, U.S.A.
  • Champagne AA; Department of Orthopedic Surgery, Queen's University, Kingston, Ontario, Canada; School of Medicine, Queen's University, Kingston, Ontario, Canada.
  • Myer GD; Department of Orthopaedics, Emory University School of Medicine, Atlanta, Georgia, USA; Emory Sports Performance and Research Center (SPARC), Flowery Branch, Georgia, U.S.A.; Emory Sports Medicine Center, Atlanta, Georgia, U.S.A.; The Micheli Center for Sports Injury Prevention, Waltham, Massachuset
  • Kaiser J; Department of Orthopaedics, Emory University School of Medicine, Atlanta, Georgia, USA.
  • Lamplot JD; Campbell Clinic, Memphis, Tennessee, U.S.A.. Electronic address: jlamplot@campbellclinic.com.
Arthroscopy ; 40(1): 124-132, 2024 01.
Article em En | MEDLINE | ID: mdl-37355190
ABSTRACT

PURPOSE:

To compare the time-zero biomechanical properties of hamstring graft preparations with or without suture augmentation for anterior cruciate ligament reconstruction (ACLR) in a full-construct cadaveric model.

METHODS:

Hamstring grafts were harvested from 24 fresh frozen human cadavers and prepared in 1 of 3 ways quadrupled SemiTendinosus (SemiT), and quadrupled SemiT with suture augmentation (SemiT+2.0-mm tape or SemiT+1.3-mm tape; n = 8 per group). Adjustable loop suspensory implants and cortical buttons were used for fixation on a porcine tibia and acrylic block. Testing included force-controlled cyclic loading at 250 N and 400 N followed by load to failure.

RESULTS:

The 2 suture augmentation groups had less total elongation and increased stiffness compared to the nonsuture-augmented group (P = .025). The SemiT+2.0-mm tape group had 36% less total elongation and 34% increased stiffness compared to SemiT+1.3mm tape (P < .001).

CONCLUSIONS:

Suture augmentation improves construct biomechanics at time zero following hamstring tendon ACLR. Augmentation with 2.0-mm tape suture improves construct biomechanics compared to 1.3-mm tape suture. CLINICAL RELEVANCE Independent suture augmentation of a quadrupled SemiT graft improves ACLR construct biomechanics. Outcomes were improved with augmentation using 2.0-mm tape suture compared to 1.3-mm tape suture.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Ligamento Cruzado Anterior / Músculos Isquiossurais Limite: Animals / Humans Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Ligamento Cruzado Anterior / Músculos Isquiossurais Limite: Animals / Humans Idioma: En Ano de publicação: 2024 Tipo de documento: Article