Rapid prediction method of ZIF-8 immobilized Candida rugosa lipase activity by near-infrared spectroscopy.
Spectrochim Acta A Mol Biomol Spectrosc
; 302: 123072, 2023 Dec 05.
Article
em En
| MEDLINE
| ID: mdl-37390722
Candida rugosa lipase (CRL, EC3.1.1.3) is one of the main enzymes synthesizing esters, and ZIF-8 was chosen as an immobilization carrier for lipase. Enzyme activity testing often requires expensive reagents as substrates, and the experiment processes are time-consuming and inconvenient. As a result, a novel approach based on near-infrared spectroscopy (NIRs) was developed for predicting CRL/ZIF-8 enzyme activity. The absorbance of the immobilized enzyme catalytic system was evaluated using UV-Vis spectroscopy to investigate the amount of CRL/ZIF-8 enzyme activity. The powdered samples' near-infrared spectra were obtained. The sample's enzyme activity data were linked with each sample's original NIR spectra to establish the NIR model. A partial least squares (PLS) model of immobilized enzyme activity was developed by coupling spectral preprocessing with a variable screening technique. The experiments were completed within 48 h to eliminate inaccuracies between the reduction in enzyme activity with increasing laying-aside time throughout the test and the NIRs modeling. The root-mean-square error of cross-validation (RMSECV), the correlation coefficient of validation set (R) value, and the ratio of prediction to deviation (RPD) value were employed as assessment model indicators. The near-infrared spectrum model was developed by merging the best 2nd derivative spectral preprocessing with the Competitive Adaptive Reweighted Sampling (CARS) variable screening method. This model's root-mean-square error of cross-validation (RMSECV) was 0.368 U/g, the correlation coefficient of calibration set (R_cv) value was 0.943, the root-mean-square error of prediction (RMSEP) set was 0.414 U/g, the correlation coefficient of validation set (R) value was 0.952, and the ratio of prediction to deviation (RPD) was 3.0. The model demonstrates that the fitting relationship between the predicted and the reference enzyme activity value of the NIRs is satisfactory. The findings revealed a strong relationship between NIRs and CRL/ZIF-8 enzyme activity. As a result, the established model could be implemented to quantify the enzyme activity of CRL/ZIF-8 quickly by including more variations of natural samples. The prediction method is simple, rapid, and adaptable to be the theoretical and practical basis for further studying other interdisciplinary research work in enzymology and spectroscopy.
Palavras-chave
Texto completo:
1
Base de dados:
MEDLINE
Assunto principal:
Espectroscopia de Luz Próxima ao Infravermelho
/
Enzimas Imobilizadas
Tipo de estudo:
Prognostic_studies
/
Risk_factors_studies
Idioma:
En
Ano de publicação:
2023
Tipo de documento:
Article