Ultra-High-Resolution Time-of-Flight MR-Angiography for the Noninvasive Assessment of Intracranial Aneurysms, Alternative to Preinterventional DSA?
Clin Neuroradiol
; 33(4): 1115-1122, 2023 Dec.
Article
em En
| MEDLINE
| ID: mdl-37401949
PURPOSE: The 3D time-of-flight (TOF) magnetic resonance angiography (MRA) at 3T shows high sensitivity for intracranial aneurysms but is inferior to three-dimensional digital subtraction angiography (3D-DSA) regarding aneurysm characteristics. We applied an ultra-high-resolution (UHR) TOF-MRA using compressed sensing reconstruction to investigate the diagnostic performance in preinterventional evaluation of intracranial aneurysms compared to conventional TOF-MRA and 3D-DSA. METHODS: In this study 17 patients with unruptured intracranial aneurysms were included. Aneurysm dimensions, configuration, image quality and sizing of endovascular devices were compared between conventional TOF-MRA at 3T and UHR-TOF with 3D-DSA as gold standard. Quantitatively, contrast-to-noise ratios (CNR) were compared between TOF-MRAs. RESULTS: On 3D-DSA, 25 aneurysms in 17 patients were detected. On conventional TOF, 23 aneurysms were detected (sensitivity: 92.6%). On UHR-TOF, 25 aneurysms were detected (sensitivity: 100%). Image quality was not significantly different between TOF and UHR-TOF (pâ¯= 0.17). Aneurysm dimension measurements were significantly different between conventional TOF (3.89â¯mm) and 3D-DSA (4.2â¯mm, pâ¯= 0.08) but not between UHR-TOF (4.12â¯mm) and 3D-DSA (pâ¯= 0.19). Irregularities and small vessels at the aneurysm neck were more frequently correctly depicted on UHR-TOF compared to conventional TOF. Comparison of the planned framing coil diameter and flow-diverter (FD) diameter revealed neither a statistically significant difference between TOF and 3D-DSA (coil pâ¯= 0.19, FD pâ¯= 0.45) nor between UHR-TOF and 3D-DSA (coil: pâ¯= 0.53, FD 0.33). The CNR was significantly higher in conventional TOF (pâ¯= 0.009). CONCLUSION: In this pilot study, ultra-high-resolution TOF-MRA visualized all aneurysms and accurately depicted aneurysm irregularities and vessels at the base of the aneurysm comparably to DSA, outperforming conventional TOF. UHR-TOF with compressed sensing reconstruction seems to represent a non-invasive alternative to pre-interventional DSA for intracranial aneurysms.
Palavras-chave
Texto completo:
1
Base de dados:
MEDLINE
Assunto principal:
Aneurisma Intracraniano
/
Embolização Terapêutica
Limite:
Humans
Idioma:
En
Ano de publicação:
2023
Tipo de documento:
Article