Your browser doesn't support javascript.
loading
Repeatability and Reproducibility of Potential Ultrasonographic Bishop Score Parameters.
Mlodawski, Jakub; Mlodawska, Marta; Plusajska, Justyna; Detka, Karolina; Bialek, Katarzyna; Swiercz, Grzegorz.
Afiliação
  • Mlodawski J; Collegium Medicum, Jan Kochanowski University, 25-369 Kielce, Poland.
  • Mlodawska M; Clinic of Obstetrics and Gynaecology, Provincial Combined Hospital in Kielce, 25-736 Kielce, Poland.
  • Plusajska J; Collegium Medicum, Jan Kochanowski University, 25-369 Kielce, Poland.
  • Detka K; Collegium Medicum, Jan Kochanowski University, 25-369 Kielce, Poland.
  • Bialek K; Clinic of Obstetrics and Gynaecology, Provincial Combined Hospital in Kielce, 25-736 Kielce, Poland.
  • Swiercz G; Clinic of Obstetrics and Gynaecology, Provincial Combined Hospital in Kielce, 25-736 Kielce, Poland.
J Clin Med ; 12(13)2023 Jul 05.
Article em En | MEDLINE | ID: mdl-37445532
ABSTRACT
Determination of the Bishop score (BS) is a traditional method of assessing the cervix in obstetrics and gynecology. This examination is characterized by subjectivity of assessment and low repeatability. In scientific studies intended to evaluate the results of the procedure based on the initial assessment, it is necessary to find an objective scale based on ultrasonography. We selected five ultrasound parameters, measured with a transvaginal transducer, that are equivalent to the individual BS axes (dilatation assessed in three-dimensional ultrasound (DL), angle of progression (AoP), vagino-cervical angle (VCA), strain elastography using the E-Cervix module, and cervical length (CL)). All selected parameters were characterized by good to excellent repeatability (intraclass correlation coefficient (ICC) = 0.878-0.994) and reproducibility (ICC = 0.826-0.996). Each of the selected parameters significantly correlated with its corresponding BS axis. The highest value of the correlation coefficient was achieved with CL (-0.75) and DL (0.71). Other parameters were characterized by an average to high correlation (AoP and station = 0.69, hardness ratio and consistency = -0.33, position and VCA = -0.38). The best correlation with the sum of the BS points was exhibited by AoP (0.52) and CL (-0.61). The selected ultrasound parameters analogous to the BS axes were characterized by high repeatability and significant correlation with the axes of the original clinical BS. Further research into the predictive properties of a multivariate model based on these parameters is needed.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Tipo de estudo: Prognostic_studies Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Tipo de estudo: Prognostic_studies Idioma: En Ano de publicação: 2023 Tipo de documento: Article