Your browser doesn't support javascript.
loading
An Interim 6-Month Analysis of the Dermatologic Effects and Midface Volume Correction With XTR CL Filler in a Prospective, Single-Center Study.
Salti, Giovanni; Siquier-Dameto, Gabriel; Rharbaoui, Siham; Hernandez Malgapo, Dennis Malvin; Innocenti, Silvia; Manni, Martina.
Afiliação
  • Salti G; Aesthetic Medicine Section, Medlight Istituto Medico, Florence, Italy.
  • Siquier-Dameto G; Dameto Clinics International, Amsterdam, the Netherlands.
  • Rharbaoui S; Dameto Clinics International, Campanet, Spain.
  • Hernandez Malgapo DM; Clinical Anatomy, Embryology and Neuroscience (NEOMA), Department of Medical Sciences, Universitat de Girona (UdG), Girona, Spain.
  • Innocenti S; Eurofins-Dermscan, Villeurbanne, France.
  • Manni M; Skinsoul Advanced Dermatology and Medical Aesthetics, Quezon City, Metro Manila, Philippines; and.
Dermatol Surg ; 49(10): 943-948, 2023 10 01.
Article em En | MEDLINE | ID: mdl-37450665
BACKGROUND: Hyaluronic acid-based filler injections with parenteral anesthetics have become the standard in treating midface volume deficits. There are currently limited data on the effects of these types of fillers on skin density, thickness, and firmness. OBJECTIVE: This study aimed to assess the efficacy of XTR CL filler in improving skin quality and tissue volume in women with midface volume loss. MATERIALS AND METHODS: In this prospective, noncomparative, single-center study, 50 women aged between 40 and 60 years with midface volume loss were recruited. The primary endpoint was the improvement in investigator-assessed Global Aesthetic Improvement Scores (GAIS) 1 month after treatment. Secondary endpoints include objective measurements of skin density, thickness, and quality measurements, facial and/or cheek volume augmentation, subjective GAIS, and device evaluation from after the first injection until 6 months, and the documentation of injection site reactions and adverse events. RESULTS: XTR CL use led to significant improvement in midface volume deficits, and skin quality and skin thickness. Injector and subject satisfaction with the treatment were documented and only mild-to-moderate adverse reactions were reported. CONCLUSION: XTR CL was shown to be effective in improving volume loss and skin quality at 6 months.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Envelhecimento da Pele / Técnicas Cosméticas / Preenchedores Dérmicos Tipo de estudo: Observational_studies Limite: Adult / Female / Humans / Middle aged Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Envelhecimento da Pele / Técnicas Cosméticas / Preenchedores Dérmicos Tipo de estudo: Observational_studies Limite: Adult / Female / Humans / Middle aged Idioma: En Ano de publicação: 2023 Tipo de documento: Article