Your browser doesn't support javascript.
loading
Continuous positive airway pressure and adherence in patients with different endotypes of obstructive sleep apnea.
Cheng, Wan-Ju; Finnsson, Eysteinn; Ágústsson, Jón S; Sands, Scott A; Hang, Liang-Wen.
Afiliação
  • Cheng WJ; Department of Psychiatry, China Medical University Hospital, Taichung, Taiwan.
  • Finnsson E; Department of Public Health, China Medical University, Taichung, Taiwan.
  • Ágústsson JS; National Center for Geriatrics and Welfare Research, National Health Research Institutes, Miaoli, Taiwan.
  • Sands SA; Nox Research, Nox Medical ehf, Reykjavík, Iceland.
  • Hang LW; Nox Research, Nox Medical ehf, Reykjavík, Iceland.
J Sleep Res ; 33(1): e13999, 2024 Feb.
Article em En | MEDLINE | ID: mdl-37452710
Determining the endotypes of obstructive sleep apnea (OSA) has potential implications for precision interventions. Here we assessed whether continuous positive airway pressure (CPAP) treatment outcomes differ across endotypic subgroups. We conducted a retrospective analysis of data obtained from 225 patients with moderate-to-severe OSA from a single sleep centre. Polysomnographic and CPAP titration study data were collected between May 2020 and January 2022. One-month CPAP treatment adherence was followed. Obstructive sleep apnea endotypes, namely arousal threshold, collapsibility, loop gain, and upper airway gain were estimated from polysomnography and dichotomised as high versus low. We examined associations between endotypic subgroups and (1) optimal CPAP titration pressure, (2) CPAP-related improvements in sleep architecture (proportions of slow-wave and rapid eye movement (REM) sleep), and (3) CPAP adherence. We observed that patients with high collapsibility required a higher CPAP pressure than those with low collapsibility (∆ = 0.4 cmH2 O, 95% confidence interval [CI] = 0.3-1.7). A larger increase in slow-wave sleep and in REM sleep proportions after CPAP treatment were observed in patients with a high arousal threshold, high collapsibility, high loop gain, or high upper airway gain than in those with low levels of endotypes. High loop gain and high collapsibility were independently associated with longer CPAP use hours per night (∆ = 0.6 h, 95% CI = 0.2-1.5 and ∆ = 0.3 h, 95% CI = 0.03-1.5, respectively). In conclusion, different endotypic subgroups of OSA exhibit a difference in outcomes of CPAP treatment. Knowledge of endotypes may help clinicians to understand which patients are expected to benefit most from CPAP therapy prior to its administration.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Apneia Obstrutiva do Sono / Pressão Positiva Contínua nas Vias Aéreas Limite: Humans Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Apneia Obstrutiva do Sono / Pressão Positiva Contínua nas Vias Aéreas Limite: Humans Idioma: En Ano de publicação: 2024 Tipo de documento: Article