Your browser doesn't support javascript.
loading
Preoperative planning and intraoperative real-time navigation with indocyanine green fluorescence in robotic liver surgery.
Rompianesi, Gianluca; Pegoraro, Francesca; Ramaci, Lorenzo; Ceresa, Carlo Dl; Montalti, Roberto; Troisi, Roberto I.
Afiliação
  • Rompianesi G; Division of Hepato-Biliary-Pancreatic, Minimally Invasive and Robotic Surgery and Kidney Transplantation, Department of Clinical Medicine and Surgery, Federico II University Hospital, via S. Pansini n. 5, Naples, Italy. gianlucarompianesi@gmail.com.
  • Pegoraro F; Division of Hepato-Biliary-Pancreatic, Minimally Invasive and Robotic Surgery and Kidney Transplantation, Department of Clinical Medicine and Surgery, Federico II University Hospital, via S. Pansini n. 5, Naples, Italy.
  • Ramaci L; Division of Hepato-Biliary-Pancreatic, Minimally Invasive and Robotic Surgery and Kidney Transplantation, Department of Clinical Medicine and Surgery, Federico II University Hospital, via S. Pansini n. 5, Naples, Italy.
  • Ceresa CD; Nuffield Department of Surgical Sciences, University of Oxford, Oxford, UK.
  • Montalti R; Division of Hepato-Biliary-Pancreatic, Minimally Invasive and Robotic Surgery and Kidney Transplantation, Department of Public Health Federico II University Hospital, Naples, Italy.
  • Troisi RI; Division of Hepato-Biliary-Pancreatic, Minimally Invasive and Robotic Surgery and Kidney Transplantation, Department of Clinical Medicine and Surgery, Federico II University Hospital, via S. Pansini n. 5, Naples, Italy.
Langenbecks Arch Surg ; 408(1): 292, 2023 Jul 31.
Article em En | MEDLINE | ID: mdl-37522938
ABSTRACT

PURPOSE:

We aimed at exploring indocyanine green (ICG) fluorescence wide spectrum of applications in hepatobiliary surgery as can result particularly useful in robotic liver resections (RLR) in order to overcome some technical limitations, increasing safety, and efficacy.

METHODS:

We describe our experience of 76 RLR performed between March 2020 and December 2022 exploring all the possible applications of pre- and intraoperative ICG administration.

RESULTS:

Hepatocellular carcinoma and colorectal liver metastases were the most common indications for RLR (34.2% and 26.7% of patients, respectively), and 51.3% of cases were complex resections with high IWATE difficulty scores. ICG was administered preoperatively in 61 patients (80.3%), intraoperatively in 42 patients (55.3%) and in both contexts in 25 patients (32.9%), with no observed adverse events. The most frequent ICG goal was to achieve tumor enhancement (59 patients, 77.6%), with a success rate of 94.9% and the detection of 3 additional malignant lesions. ICG facilitated evaluation of the resection margin for residual tumor and perfusion adequacy in 33.9% and 32.9% of cases, respectively, mandating a resection enlargement in 7.9% of patients. ICG fluorescence allowed the identification of the transection plane through negative staining in the 25% of cases. Vascular and biliary structures were visualized in 21.1% and 9.2% of patients, with a success rate of 81.3% and 85.7%, respectively.

CONCLUSION:

RLR can benefit from the routine integration of ICG fluoresce evaluation according to each individual patient and condition-specific goals and issues, allowing liver functional assessment, anatomical and vascular evaluation, tumor detection, and resection margins assessment.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Robótica / Procedimentos Cirúrgicos Robóticos Tipo de estudo: Prognostic_studies Limite: Humans Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Robótica / Procedimentos Cirúrgicos Robóticos Tipo de estudo: Prognostic_studies Limite: Humans Idioma: En Ano de publicação: 2023 Tipo de documento: Article