Detection of vitrector shavings on OCT.
Silvasi, Truman L; Omari, Amro A; Sitto, Mina M; Gupta, Chirag K; Williams, George A.
Afiliação
  • Silvasi TL; Oakland University William Beaumont School of Medicine, Royal Oak, Michigan, USA.
  • Omari AA; Beaumont Eye Institute, Royal Oak, Michigan, USA.
  • Sitto MM; Oakland University William Beaumont School of Medicine, Royal Oak, Michigan, USA.
  • Gupta CK; Beaumont Eye Institute, Royal Oak, Michigan, USA.
  • Williams GA; Wayne State University School of Medicine, Detroit, Michigan, USA.
Article em En | MEDLINE | ID: mdl-37527502
ABSTRACT

PURPOSE:

To describe multiple retained intraocular foreign bodies felt to be from a vitrectomy instrument.

METHODS:

Observational case report. PATIENT A 66-year-old male with history of rhegmatogenous retinal detachment repaired with PPV, scleral buckle, endolaser, and fluid-air exchange presented with dyschromatopsia OD.

RESULTS:

OCT demonstrated metallic vitrector shavings detected on OCT above the optic nerve head and macula. Repeat OCT 9 months later demonstrated movement of the vitrector shavings throughout the vitreous.

CONCLUSION:

We demonstrate retained intraocular foreign body shavings which are rarely seen following vitrectomy. These can be confirmed using OCT.