Your browser doesn't support javascript.
loading
RART-LAMP: One-Step Extraction-Free Method for Genotyping within 40 min.
Zhang, Zhang; Guan, Luhao; Yao, Juan; Li, Lijia; Liu, Chunfang; Guo, Yongcan; Xie, Guoming.
Afiliação
  • Zhang Z; Key Laboratory of Clinical Laboratory Diagnostics (Chinese Ministry of Education), College of Laboratory Medicine, Chongqing Medical Laboratory Microfluidics and SPRi Engineering Research Center, Chongqing Medical University, Chongqing 400016, China.
  • Guan L; Key Laboratory of Clinical Laboratory Diagnostics (Chinese Ministry of Education), College of Laboratory Medicine, Chongqing Medical Laboratory Microfluidics and SPRi Engineering Research Center, Chongqing Medical University, Chongqing 400016, China.
  • Yao J; Department of Laboratory Medicine, Luzhou Traditional Chinese Medicine Hospital, Luzhou 646000, China.
  • Li L; Department of Laboratory Medicine, The Affiliated Traditional Chinese Medicine Hospital of Southwest Medical University, Luzhou 646000, China.
  • Liu C; Zhuhai Biori Biotechnology Company Limited, Zhuhai 519000, China.
  • Guo Y; Zhuhai Biori Biotechnology Company Limited, Zhuhai 519000, China.
  • Xie G; Department of Laboratory Medicine, The Affiliated Traditional Chinese Medicine Hospital of Southwest Medical University, Luzhou 646000, China.
Anal Chem ; 95(33): 12487-12496, 2023 08 22.
Article em En | MEDLINE | ID: mdl-37534990
ABSTRACT
Loop-mediated isothermal amplification (LAMP) is a commonly used alternative to PCR for point-of-care detection of nucleic acids due to its rapidity, sensitivity, specificity, and simpler instrumentation. While dual-labeled TaqMan probes are widely used in PCR for single-nucleotide polymorphism (SNP) genotyping, real-time LAMP primarily relies on turbidimetry or intercalator fluorescence measurements, which can be non-specific and generate false-positive results. In this study, we propose a closed-tube, dual-labeled RNA-modified probes and RNase H II-assisted real-time LAMP (RART-LAMP) method for SNP genotyping. Our findings indicate that (1) fluorescence signals were predominantly derived from probe hydrolysis rather than hybridization, (2) temperature-controlled hybridization between the probe and template ensured the specificity of SNP analysis, and (3) RNase H II hydrolysis between the target containing SNP sites and probes did not exhibit sequence specificity. Our RART-LAMP approach demonstrated excellent performance in genotyping C677T clinical samples, including gDNA extracted from blood, saliva, and swabs. More importantly, saliva and swab samples could be directly analyzed without any pretreatment, indicating promising prospects for nucleic acid analysis at the point of care in resource-limited settings.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Polimorfismo de Nucleotídeo Único / Técnicas de Amplificação de Ácido Nucleico Tipo de estudo: Diagnostic_studies Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Polimorfismo de Nucleotídeo Único / Técnicas de Amplificação de Ácido Nucleico Tipo de estudo: Diagnostic_studies Idioma: En Ano de publicação: 2023 Tipo de documento: Article