In Vivo Thermal Ablation of Deep Intrahepatic Targets Using a Super-Convergent MRgHIFU Applicator and a Pseudo-Tumor Model.
Lorton, Orane; Guillemin, Pauline Coralie; Peloso, Andrea; M'Rad, Yacine; Crowe, Lindsey Alexandra; Koessler, Thibaud; Poletti, Pierre-Alexandre; Boudabbous, Sana; Ricoeur, Alexis; Salomir, Rares.
Afiliação
  • Lorton O; Image Guided Interventions Laboratory (GR-949), Faculty of Medicine, University of Geneva, 1211 Geneva, Switzerland.
  • Guillemin PC; Image Guided Interventions Laboratory (GR-949), Faculty of Medicine, University of Geneva, 1211 Geneva, Switzerland.
  • Peloso A; Visceral Surgery Division, University Hospitals of Geneva, 1205 Geneva, Switzerland.
  • M'Rad Y; Image Guided Interventions Laboratory (GR-949), Faculty of Medicine, University of Geneva, 1211 Geneva, Switzerland.
  • Crowe LA; Radiology Division, University Hospitals of Geneva, 1205 Geneva, Switzerland.
  • Koessler T; Oncology Department, University Hospitals of Geneva, 1205 Geneva, Switzerland.
  • Poletti PA; Radiology Division, University Hospitals of Geneva, 1205 Geneva, Switzerland.
  • Boudabbous S; Image Guided Interventions Laboratory (GR-949), Faculty of Medicine, University of Geneva, 1211 Geneva, Switzerland.
  • Ricoeur A; Radiology Division, University Hospitals of Geneva, 1205 Geneva, Switzerland.
  • Salomir R; Image Guided Interventions Laboratory (GR-949), Faculty of Medicine, University of Geneva, 1211 Geneva, Switzerland.
Cancers (Basel) ; 15(15)2023 Aug 03.
Article em En | MEDLINE | ID: mdl-37568777
ABSTRACT

BACKGROUND:

HIFU ablation of liver malignancies is particularly challenging due to respiratory motion, high tissue perfusion and the presence of the rib cage. Based on our previous development of a super-convergent phased-array transducer, we aimed to further investigate, in vivo, its applicability to deep intrahepatic targets.

METHODS:

In a series of six pigs, a pseudo-tumor model was used as target, visible both on intra-operatory MRI and post-mortem gross pathology. The transcostal MRgHIFU ablation was prescribed coplanar with the pseudo-tumor, either axial or sagittal, but deliberately shifted 7 to 18 mm to the side. No specific means of protection of the ribs were implemented. Post-treatment MRI follow-up was performed at D7, followed by animal necropsy and gross pathology of the liver.

RESULTS:

The pseudo-tumor was clearly identified on T1w MR imaging and subsequently allowed the MRgHIFU planning. The peak temperature at the focal point ranged from 58-87 °C. Gross pathology confirmed the presence of the pseudo-tumor and the well-delineated MRgHIFU ablation at the expected locations.

CONCLUSIONS:

The specific design of the transducer enabled a reliable workflow. It demonstrated a good safety profile for in vivo transcostal MRgHIFU ablation of deep-liver targets, graded as challenging for standard surgery.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2023 Tipo de documento: Article