Your browser doesn't support javascript.
loading
Overcoming Soluble Target Interference in Measurement of Total Bispecific Therapeutic Antibody Concentrations.
Shim, Jeongsup; Chen, Jessica; Carrasco-Triguero, Montserrat; Fischer, Saloumeh K.
Afiliação
  • Shim J; BioAnalytical Sciences, Development Sciences, Genentech, Inc., 1 DNA Way, South San Francisco, California, 94080, USA. shim.jeongsup@gene.com.
  • Chen J; BioAnalytical Sciences, Development Sciences, Genentech, Inc., 1 DNA Way, South San Francisco, California, 94080, USA.
  • Carrasco-Triguero M; BioAnalytical Sciences, Development Sciences, Genentech, Inc., 1 DNA Way, South San Francisco, California, 94080, USA.
  • Fischer SK; BioAnalytical Sciences, Development Sciences, Genentech, Inc., 1 DNA Way, South San Francisco, California, 94080, USA.
AAPS J ; 25(5): 82, 2023 08 18.
Article em En | MEDLINE | ID: mdl-37594571
The measurement of therapeutic drug concentrations is used to assess drug exposure and the relationship between therapeutic pharmacokinetics (PK) and pharmacodynamics (PD), which help determine the optimal dose for patients. Ligand binding assays (LBAs) are often the method of choice for evaluation of drug concentration and use either the therapeutic target protein or antibodies to the therapeutic as capture and/or detection reagents. Due to the bivalency of antibody therapeutics, heterogeneous states of the drug/target complex can exist in the presence of soluble targets which can complicate measurement of unbound drug. In the case of bispecific antibodies, measurement of drug can be even more complicated and depend upon the levels of both targets to each arm. Measuring the total drug allows for PKPD modeling prediction of human dose projections in addition to overcoming challenges associated with measuring free drug for bispecific antibodies. Here, we present a study in which a sandwich ELISA format was used to measure total anti-KLK5/KLK7 antibody concentrations. This assay utilized a non-blocking anti-idiotype (ID) antibody to one arm of the antibody for capture and an antibody to target bound to the other arm of the antibody for detection. Our qualified assay showed acceptable precision, accuracy, dilutional linearity, and reproducibility and enabled detection of a total bispecific antibody at high levels of two targets. To confirm that our assay was detecting total drug, a subset of samples was evaluated in a generic total LC-MS/MS assay.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Anticorpos Biespecíficos Tipo de estudo: Prognostic_studies Limite: Humans Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Anticorpos Biespecíficos Tipo de estudo: Prognostic_studies Limite: Humans Idioma: En Ano de publicação: 2023 Tipo de documento: Article