Your browser doesn't support javascript.
loading
Nanozyme-Mediated Catalytic Signal Amplification for Microfluidic Biosensing of Foodborne Bacteria.
Xing, Gaowa; Shang, Yuting; Ai, Jiebing; Lin, Haifeng; Wu, Zengnan; Zhang, Qiang; Lin, Jin-Ming; Pu, Qiaosheng; Lin, Ling.
Afiliação
  • Xing G; College of Chemistry and Chemical Engineering, Lanzhou University, Lanzhou 730000, China.
  • Shang Y; Beijing Key Laboratory of Microanalysis Methods and Instrumentation, Department of Chemistry, Tsinghua University, Beijing 100084, China.
  • Ai J; Beijing Key Laboratory of Microanalysis Methods and Instrumentation, Department of Chemistry, Tsinghua University, Beijing 100084, China.
  • Lin H; College of Chemistry and Chemical Engineering, Lanzhou University, Lanzhou 730000, China.
  • Wu Z; Department of Bioengineering, Beijing Technology and Business University, Beijing 100048, China.
  • Zhang Q; Beijing Key Laboratory of Microanalysis Methods and Instrumentation, Department of Chemistry, Tsinghua University, Beijing 100084, China.
  • Lin JM; Beijing Key Laboratory of Microanalysis Methods and Instrumentation, Department of Chemistry, Tsinghua University, Beijing 100084, China.
  • Pu Q; Beijing Key Laboratory of Microanalysis Methods and Instrumentation, Department of Chemistry, Tsinghua University, Beijing 100084, China.
  • Lin L; College of Chemistry and Chemical Engineering, Lanzhou University, Lanzhou 730000, China.
Anal Chem ; 95(35): 13391-13399, 2023 09 05.
Article em En | MEDLINE | ID: mdl-37610722
Early detection of foodborne bacteria is urgently needed to ensure food quality and to avoid the outbreak of foodborne bacterial diseases. Here, a kind of metal-organic framework (Zr-MOF) modified with Pt nanoparticles (Pt-PCN-224) was designed as a peroxidase-like signal amplifier for microfluidic biosensing of foodborne bacteria. Taking Escherichia coli (E. coli) O157:H7 as a model, a linear range from 2.93 × 102 to 2.93 × 108 CFU/mL and a limit of detection of 2 CFU/mL were obtained. The whole detection procedure was integrated into a single microfluidic chip. Water, milk, and cabbage samples were successfully detected, showing consistency with the results of the standard culture method. Recoveries were in the range from 90 to 110% in spiked testing. The proposed microfluidic biosensor realized the specific and sensitive detection of E. coli O157:H7 within 1 h, implying broad prospects of MOF with biomimetic enzyme activities for biosensing.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Escherichia coli O157 / Doenças Transmitidas por Alimentos Tipo de estudo: Screening_studies Limite: Humans Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Escherichia coli O157 / Doenças Transmitidas por Alimentos Tipo de estudo: Screening_studies Limite: Humans Idioma: En Ano de publicação: 2023 Tipo de documento: Article