AI-based, automated chamber volumetry from gated, non-contrast CT.
Jacob, Athira J; Abdelkarim, Ola; Zook, Salma; Kragholm, Kristian Hay; Gupta, Prantik; Cocker, Myra; Giraldo, Juan Ramirez; Doherty, Jim O; Schoebinger, Max; Schwemmer, Chris; Gulsun, Mehmet A; Rapaka, Saikiran; Sharma, Puneet; Chang, Su-Min.
Afiliação
  • Jacob AJ; Digital Technology and Innovation, Siemens Healthineers, Princeton, NJ, USA.
  • Abdelkarim O; Houston Methodist Hospital, Houston, TX, USA.
  • Zook S; Houston Methodist Hospital, Houston, TX, USA.
  • Kragholm KH; Houston Methodist Hospital, Houston, TX, USA.
  • Gupta P; Digital Technology and Innovation, Siemens Healthineers, Princeton, NJ, USA.
  • Cocker M; CT R&D Collaborations, Siemens Healthineers, Malvern, PA, USA.
  • Giraldo JR; CT R&D Collaborations, Siemens Healthineers, Malvern, PA, USA.
  • Doherty JO; CT R&D Collaborations, Siemens Healthineers, Malvern, PA, USA.
  • Schoebinger M; Siemens Healthineers, Forchheim, Germany.
  • Schwemmer C; Siemens Healthineers, Forchheim, Germany.
  • Gulsun MA; Digital Technology and Innovation, Siemens Healthineers, Princeton, NJ, USA.
  • Rapaka S; Digital Technology and Innovation, Siemens Healthineers, Princeton, NJ, USA.
  • Sharma P; Digital Technology and Innovation, Siemens Healthineers, Princeton, NJ, USA.
  • Chang SM; Houston Methodist Hospital, Houston, TX, USA. Electronic address: SMChang@houstonmethodist.org.
J Cardiovasc Comput Tomogr ; 17(5): 336-340, 2023.
Article em En | MEDLINE | ID: mdl-37612232
ABSTRACT

BACKGROUND:

Accurate chamber volumetry from gated, non-contrast cardiac CT (NCCT) scans can be useful for potential screening of heart failure.

OBJECTIVES:

To validate a new, fully automated, AI-based method for cardiac volume and myocardial mass quantification from NCCT scans compared to contrasted CT Angiography (CCTA).

METHODS:

Of a retrospectively collected cohort of 1051 consecutive patients, 420 patients had both NCCT and CCTA scans at mid-diastolic phase, excluding patients with cardiac devices. Ground truth values were obtained from the CCTA scans.

RESULTS:

The NCCT volume computation shows good agreement with ground truth values. Volume differences [95% CI ] and correlation coefficients were -9.6 [-45; 26] mL, r â€‹= â€‹0.98 for LV Total, -5.4 [-24; 13] mL, r â€‹= â€‹0.95 for LA, -8.7 [-45; 28] mL, r â€‹= â€‹0.94 for RV, -5.2 [-27; 17] mL, r â€‹= â€‹0.92 for RA, -3.2 [-42; 36] mL, r â€‹= â€‹0.91 for LV blood pool, and -6.7 [-39; 26] g, r â€‹= â€‹0.94 for LV wall mass, respectively. Mean relative volume errors of less than 7% were obtained for all chambers.

CONCLUSIONS:

Fully automated assessment of chamber volumes from NCCT scans is feasible and correlates well with volumes obtained from contrast study.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Tomografia Computadorizada por Raios X / Angiografia por Tomografia Computadorizada Limite: Humans Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Tomografia Computadorizada por Raios X / Angiografia por Tomografia Computadorizada Limite: Humans Idioma: En Ano de publicação: 2023 Tipo de documento: Article