Your browser doesn't support javascript.
loading
Multiple miRNA Detection through a Suspended Microbead Array Encoded by Triple-Color Upconversion Luminescent Nanotags via Bi-Beam Splitter Hybrid-Multitrap Optical Tweezers.
Yu, He; Jia, Zeng-Shuai; Xu, Peng-Fei; Liu, Yang; Xu, Da-Di; Li, Yu-Yao; Tang, Hong-Wu.
Afiliação
  • Yu H; College of Chemistry and Molecular Sciences, Wuhan University, Wuhan 430072, People's Republic of China.
  • Jia ZS; School of Information Management, Wuhan University, Wuhan 430072, People's Republic of China.
  • Xu PF; College of Chemistry and Molecular Sciences, Wuhan University, Wuhan 430072, People's Republic of China.
  • Liu Y; College of Chemistry and Molecular Sciences, Wuhan University, Wuhan 430072, People's Republic of China.
  • Xu DD; College of Chemistry and Molecular Sciences, Wuhan University, Wuhan 430072, People's Republic of China.
  • Li YY; College of Chemistry and Molecular Sciences, Wuhan University, Wuhan 430072, People's Republic of China.
  • Tang HW; College of Chemistry and Molecular Sciences, Wuhan University, Wuhan 430072, People's Republic of China.
Anal Chem ; 95(37): 14086-14093, 2023 09 19.
Article em En | MEDLINE | ID: mdl-37665143
ABSTRACT
In recent years, optical tweezers have become a novel tool for biodetection, and to improve the inefficiency of a single trap, the development of multitraps is required. Herein, we constructed a set of hybrid multitrap optical tweezers with the balance of stability and flexibility by the combination of two different beam splitters, a diffraction optical element (DOE) and galvano mirrors (GMs), to capture polystyrene (PS) microbeads in aqueous solutions to create an 18-trap suspended array. A sandwich hybridization strategy of DNA-miRNA-DNA was adopted to detect three kinds of target miRNAs associated with triple negative breast cancer (TNBC), in which different upconversion nanoparticles (UCNPs) with red, green, and blue emissions were applied as luminescent tags to encode the carrier PS microbeads to further indicate the levels of the targets. With encoded luminescent microbeads imaged by a three-channel microscopic system, the biodetection displayed high sensitivity with low limits of detection (LODs) of 0.27, 0.32, and 0.33 fM and exceptional linear ranges of 0.5 fM to 1 nM, 0.7 fM to 1 nM, and 1 fM to 1 nM for miR-343-3p, miR-155, and miR-199a-5p, respectively. In addition, this bead-based assay method was demonstrated to have the potential for being applied in patients' serum by satisfactory standard addition recovery experiment results.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: MicroRNAs Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: MicroRNAs Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Ano de publicação: 2023 Tipo de documento: Article