Your browser doesn't support javascript.
loading
Performance Characteristics of a Rule-Based Electronic Health Record Algorithm to Identify Patients with Gross and Microscopic Hematuria.
Kashkoush, Jasmine; Gupta, Mudit; Meissner, Matthew A; Nielsen, Matthew E; Kirchner, H Lester; Garg, Tullika.
Afiliação
  • Kashkoush J; Department of Urology, Geisinger, Danville, Pennsylvania, United States.
  • Gupta M; Phenomic Analytics and Clinical Data Core, Geisinger, Danville, Pennsylvania, United States.
  • Meissner MA; Department of Urology, Geisinger, Danville, Pennsylvania, United States.
  • Nielsen ME; Department of Urology, University of North Carolina at Chapel Hill School of Medicine, Chapel Hill, North Carolina, United States.
  • Kirchner HL; Department of Epidemiology, University of North Carolina at Chapel Hill, Gillings School of Global Public Health, Chapel Hill, North Carolina, United States.
  • Garg T; Department of Health Policy & Management, University of North Carolina at Chapel Hill, Gillings School of Global Public Health, Chapel Hill, North Carolina, United States.
Methods Inf Med ; 62(5-06): 183-192, 2023 12.
Article em En | MEDLINE | ID: mdl-37666279
ABSTRACT

BACKGROUND:

Two million patients per year are referred to urologists for hematuria, or blood in the urine. The American Urological Association recently adopted a risk-stratified hematuria evaluation guideline to limit multi-phase computed tomography to individuals at highest risk of occult malignancy.

OBJECTIVES:

To understand population-level hematuria evaluations, we developed an algorithm to accurately identify hematuria cases from electronic health records (EHRs).

METHODS:

We used International Classification of Diseases (ICD)-9/ICD-10 diagnosis codes, urine color, and urine microscopy values to identify hematuria cases and to differentiate between gross and microscopic hematuria. Using an iterative process, we refined the ICD-9 algorithm on a gold standard, chart-reviewed cohort of 3,094 hematuria cases, and the ICD-10 algorithm on a 300 patient cohort. We applied the algorithm to Geisinger patients ≥35 years (n = 539,516) and determined performance by conducting chart review (n = 500).

RESULTS:

After applying the hematuria algorithm, we identified 51,500 hematuria cases and 488,016 clean controls. Of the hematuria cases, 11,435 were categorized as gross, 26,658 as microscopic, 12,562 as indeterminate, and 845 were uncategorized. The positive predictive value (PPV) of identifying hematuria cases using the algorithm was 100% and the negative predictive value (NPV) was 99%. The gross hematuria algorithm had a PPV of 100% and NPV of 99%. The microscopic hematuria algorithm had lower PPV of 78% and NPV of 100%.

CONCLUSION:

We developed an algorithm utilizing diagnosis codes and urine laboratory values to accurately identify hematuria and categorize as gross or microscopic in EHRs. Applying the algorithm will help researchers to understand patterns of care for this common condition.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Registros Eletrônicos de Saúde / Hematúria Tipo de estudo: Guideline / Prognostic_studies Limite: Humans Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Registros Eletrônicos de Saúde / Hematúria Tipo de estudo: Guideline / Prognostic_studies Limite: Humans Idioma: En Ano de publicação: 2023 Tipo de documento: Article