Your browser doesn't support javascript.
loading
Dual-Channel Stretchable, Self-Tuning, Liquid Metal Coils and Their Fabrication Techniques.
Motovilova, Elizaveta; Ching, Terry; Vincent, Jana; Shin, James; Tan, Ek Tsoon; Taracila, Victor; Robb, Fraser; Hashimoto, Michinao; Sneag, Darryl B; Winkler, Simone Angela.
Afiliação
  • Motovilova E; Department of Radiology, Weill Cornell Medicine, New York, NY 10065, USA.
  • Ching T; Department of Radiology and Imaging, Hospital for Special Surgery, New York, NY 10021, USA.
  • Vincent J; Pillar of Engineering Product Development, Singapore University of Technology and Design, Singapore 487372, Singapore.
  • Shin J; Digital Manufacturing and Design (DManD) Centre, Singapore University of Technology and Design, Singapore 487372, Singapore.
  • Tan ET; Department of Biomedical Engineering, National University of Singapore, Singapore 117583, Singapore.
  • Taracila V; GE Healthcare, Aurora, OH 44202, USA.
  • Robb F; Department of Radiology, Weill Cornell Medicine, New York, NY 10065, USA.
  • Hashimoto M; Department of Radiology and Imaging, Hospital for Special Surgery, New York, NY 10021, USA.
  • Sneag DB; GE Healthcare, Aurora, OH 44202, USA.
  • Winkler SA; GE Healthcare, Aurora, OH 44202, USA.
Sensors (Basel) ; 23(17)2023 Sep 01.
Article em En | MEDLINE | ID: mdl-37688046
Flexible and stretchable radiofrequency coils for magnetic resonance imaging represent an emerging and rapidly growing field. The main advantage of such coil designs is their conformal nature, enabling a closer anatomical fit, patient comfort, and freedom of movement. Previously, we demonstrated a proof-of-concept single element stretchable coil design with a self-tuning smart geometry. In this work, we evaluate the feasibility of scaling this coil concept to a multi-element coil array and the associated engineering and manufacturing challenges. To this goal, we study a dual-channel coil array using full-wave simulations, bench testing, in vitro, and in vivo imaging in a 3 T scanner. We use three fabrication techniques to manufacture dual-channel receive coil arrays: (1) single-layer casting, (2) double-layer casting, and (3) direct-ink-writing. All fabricated arrays perform equally well on the bench and produce similar sensitivity maps. The direct-ink-writing method is found to be the most advantageous fabrication technique for fabrication speed, accuracy, repeatability, and total coil array thickness (0.6 mm). Bench tests show excellent frequency stability of 128 ± 0.6 MHz (0% to 30% stretch). Compared to a commercial knee coil array, the stretchable coil array is more conformal to anatomy and provides 50% improved signal-to-noise ratio in the region of interest.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Comércio / Engenharia Limite: Humans Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Comércio / Engenharia Limite: Humans Idioma: En Ano de publicação: 2023 Tipo de documento: Article