The Use of a Closed Feed Frame for the Development of Near-Infrared Spectroscopic Calibration Model to Determine Drug Concentration.
Movilla-Meza, Nathaly A; Sierra-Vega, Nobel O; Alvarado-Hernández, Bárbara B; Méndez, Rafael; Romañach, Rodolfo J.
Afiliação
  • Movilla-Meza NA; Department of Chemistry, University of Puerto Rico at Mayagüez, Mayagüez, PR, USA.
  • Sierra-Vega NO; Department of Chemical Engineering, University of Puerto Rico at Mayagüez, Mayagüez, PR, USA.
  • Alvarado-Hernández BB; Department of Chemistry, University of Puerto Rico at Mayagüez, Mayagüez, PR, USA.
  • Méndez R; Department of Chemical Engineering, University of Puerto Rico at Mayagüez, Mayagüez, PR, USA.
  • Romañach RJ; Department of Chemistry, University of Puerto Rico at Mayagüez, Mayagüez, PR, USA. rodolfoj.romanach@upr.edu.
Pharm Res ; 40(12): 2903-2916, 2023 Dec.
Article em En | MEDLINE | ID: mdl-37700106
PURPOSE: This study evaluates the use of the closed feed frame as a material sparing approach to develop near-infrared (NIR) spectroscopic calibration models for monitoring blend uniformity. The effect of shear induced by recirculation on NIR spectra was also studied. METHODS: Calibration models were developed using NIR spectra obtained in the closed feed frame for two cases. For case 2, blends that flowed through the open feed frame were predicted with the model. The shear effect of the feed frame on the blends was assessed through the characterization of powder properties before and after recirculation. RESULTS: The physical characterization of the blends confirmed that the powder properties were not altered after recirculation within the closed feed frame. Both calibration models provided highly accurate predictions of the test sets with low bias (0.03% w/w and -0.06% w/w) and relative standard error of prediction (1.9% and 3.7%), respectively. The predictive performance of the calibration models was not affected by the shear effect. CONCLUSION: Recirculation within the closed feed frame did not change the physical properties of the blends studied. The prediction of blends flowing through the open feed frame was possible with a calibration model developed in the closed feed frame. The closed feed frame could reduce the materials needed to develop calibration models by more than 90%.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Tecnologia Farmacêutica / Espectroscopia de Luz Próxima ao Infravermelho Tipo de estudo: Prognostic_studies Idioma: En Ano de publicação: 2023 Tipo de documento: Article